Spatially-resolved spectral image of a microwave-induced plasma with Okamoto-cavity for nitridation of steel substrate.
نویسندگان
چکیده
When a nitrogen microwave-induced plasma produced with an Okamoto-cavity was employed as a source for the nitridation of steel samples, the characteristics of the plasma were investigated by analyzing a spatially-resolved emission image of nitrogen excited species obtained with a two-dimensionally imaging spectrograph. Our previous study had reported on an excellent performance of the Okamoto-cavity microwave-induced plasma (MIP), enabling a nitrided layer having a several-micrometer-thickness to form on an iron substrate, even if the treatment is completed within 1 min, which is superior to a conventional plasma nitriding using low-pressure glow discharges requiring a prolonged treatment time. In this paper, the reason for this is discussed based on a spectrometric investigation. The emission images of band heads of nitrogen molecule and nitrogen molecule ion extended toward the axial/radial directions of the plasma at larger microwave powers supplied to the MIP, thus elevating the number density of the excited species of nitrogen, which would activate any chemical reaction on the iron substrate. However, a drastic increase in the growth rate of the nitrided layer when increasing the microwave power from 600 to 700 W, which had been observed in our previous study, could not be explained only from such a variation in the excited species of nitrogen. This result is probably because the growth process is dominantly controlled by thermal diffusion of nitrogen atom after it enters into the iron substrate, where the substrate temperature is the most important parameter concerning the mobility in the iron lattice. Therefore, the Okamoto-cavity MIP could contribute to a thermal source through radiative heating as well as a source of nitrogen excited species, especially in the growth process of the nitrided layer.
منابع مشابه
Characteristics of Helium Microwave-Induced Atmospheric Pressure Plasma for Fine Particle Analysis
Helium microwave-induced plasma (He-MIP) for trace element analysis is generated by a 2.45 GHz microwave power ( ~ 1 kW) with the Okamoto cavity of the surface wave mode at atmospheric pressure, and an iron excitation temperature and an electron density of the plasma are measured. With 0.8 kW input microwave power, an excitation temperature of 8000 K and the electron density of 2 x 10/cm are ob...
متن کاملPlasma-assisted oxidation, anodization, and nitridation of silicon
Plasma-assisted oxidation, anodization, and nitridation of silicon have been performed in microwave, rf, and dc plasmas with a variety of reactor configurations and a range of plasma densities. Compared to thermal processes at equivalent substrate temperatures, film growth rates are accelerated by the plasma-enhanced generation of reactive chemical species or by the presence of electric fields ...
متن کاملInvestigation of H2:CH4 Plasma Composition by Means of Spatially Resolved Optical Spectroscopy
The system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H , CH, CH) during chemical vapour deposition process. Experime...
متن کاملSpatially and temporally resolved temperature measurements of plasma generated in percussion drilling with a diode-pumped Nd:YAG laser
Results of spectroscopic temperature measurements of the laser-induced plasma generated during percussion drilling with a high power diode-pumped, pulsed Nd:YAG laser are presented. SAE 52100 steel was drilled with varying average powers. Helium and oxygen were each used as the shield gas. Emission spectra were collected with a monochrometer and an intensified charge coupled detector connected ...
متن کاملSize Distribution Measurement of Candle\'s Soot Nanoparticles by Using Time Resolved Laser Induced Incandescence
Time resolved laser induced incandescence (LII) technique is used to measure size distribution of soot nanoparticles of candle's flame. Pulsed Nd:YAG laser is used to heat nanoparticles to incandescence temperature and the resulting signal is measured. Mass and energy balance equations are numerically solved to calculate temperature of soot particles in low fluence regime. Assuming Plank black ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2014