Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters
نویسندگان
چکیده
INTRODUCTION Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control. AIM To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes. MATERIAL AND METHODS We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works™, Medikit, Japan) or standard guiding catheters (Heartrail™, Terumo, Japan). RESULTS Thirty-five patients were identified (63% men; mean age 70 ±13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 "slender mother and child" PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study. CONCLUSIONS These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters.
منابع مشابه
Successful percutaneous coronary intervention using a 4-in-3 “Slender Mother and Child” PCI technique
We report two cases of successful percutaneous coronary intervention (PCI) using a 4-in-3 "Slender Mother and Child" PCI technique. In both cases, coronary angiography revealed severe stenosis of the right coronary artery (RCA). In both cases, 5-Fr sheathless guiding catheters were inserted into the RCA (virtual 3-Fr PCI) but stents could not pass through because of stents previously implanted ...
متن کاملTransradial percutaneous coronary intervention for chronic total occlusion of coronary artery disease using sheathless standard guiding catheters
OBJECTIVES Our aim was to evaluate the feasibility and safety of routine transradial approach (TRA) percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) lesions using the sheathless technique with standard guiding catheters. BACKGROUND Transradial approach PCI was applied for CTO lesions. A major limitation of TRA CTO PCI is the inability to use large guiding catheters b...
متن کاملTransradial retrograde recanalization of totally occluded left anterior descending artery using a single 7 fr guiding catheter.
The retrograde approach for percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) has helped to improve the success rate. It is usually performed through collateral connections that originate from the contralateral coronary artery to the occluded one and by using two arterial accesses and two guiding catheters, most commonly from the femoral approach. A first reported case o...
متن کاملThe Feasibility of Percutaneous Transradial Coronary Intervention for Chronic Total Occlusion
We evaluated the feasibility of the transradial coronary intervention (TRCI) in 85 consecutive patients with chronic total occlusion (CTO). Clinical, angiographic and procedural factors were compared between the success and failure groups. An overall success rate of 65.5% (57 of 87 lesions) was achieved with TRCI, and the most common cause of failure was an inability to pass the lesion with a g...
متن کاملA Technique to Perform PCI and Stenting in an Anomalous RCA from the Left Sinus of Valsalva
This describes a technique for the successful performance of percutaneous coronary intervention in patients whose right coronary artery arises from the left sinus of Valsalva and in whom the standard guiding catheters do not allow coaxial support.
متن کامل