Comparison of Doppler ultrasonography with arteriography of the carotid artery bifurcation.
نویسندگان
چکیده
Continuous-wave (CW) Doppler ultrasound imaging for prediction of arteriogrphic abnormality at the carotid bifurcation was carried out in 195 arteries of 105 patients. The Doppler method had no predictive value when compared to angiographic findings in arteries classified as 0-50% stenosis by Doppler. In 50-75% stenosis by arteriography Doppler accuracy was 52%. With stenosis of 76-99% Doppler imaging correlated with 71% reliability. When an arteriogram was compared with Doppler imaging the latter gave a "false negative" reading in 56% and "false positive" readings in 19%. We conclude that Doppler ultrasound evaluation provides important information regarding the state of the carotid bifurcation, which supplements the bedside evaluation, but it does not substitute for arteriography.
منابع مشابه
ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی
Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...
متن کاملUltrasonic demonstration of external and internal carotid patency with common carotid occlusion: a preliminary report.
Non-invasive ultrasonic imaging of the carotid bifurcation by duplex scanning and ultrasonic arteriography combined with pulsed Doppler spectrum analysis demonstrated patency of the external and internal carotid arteries distal to a common carotid occlusion in 3 patients. Common carotid occlusion is not invariably associated with thrombosis of the ipsilateral internal carotid artery. Identifica...
متن کاملUltrasonic duplex scanning for disease of the carotid artery.
The duplex ultrasonic scanner combines real-time B-mode imaging with a single-gate, variable-range pulsed Doppler. The detection and categorization of the severity of carotid artery atherosclerosis is achieved by performing spectral analysis of the pulsed Doppler velocity signal obtained from vessels of interest. Using this technique, 750 patients with suspected extracranial carotid artery dise...
متن کاملOriginal Contributions Blinded-Reader Comparison of Magnetic Resonance Angiography and Duplex Ultrasonography for Carotid Artery Bifurcation Stenosis
Background and Purpose We compared two-dimensional time-of-flight magnetic resonance angiography (MRA) and duplex ultrasonography with arteriography for the detection of 70% to 99% stenoses at the carotid artery bifurcation (ie, surgical disease according to findings of the North American Carotid Endarterectomy Trial). Methods Three blinded readers independently measured stenoses on MRA in 73 v...
متن کاملBlinded-reader comparison of magnetic resonance angiography and duplex ultrasonography for carotid artery bifurcation stenosis.
BACKGROUND AND PURPOSE We compared two-dimensional time-of-flight magnetic resonance angiography (MRA) and duplex ultrasonography with arteriography for the detection of 70% to 99% stenoses at the carotid artery bifurcation (ie, surgical disease according to findings of the North American Carotid Endarterectomy Trial). METHODS Three blinded readers independently measured stenoses on MRA in 73...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 11 4 شماره
صفحات -
تاریخ انتشار 1980