Torsional properties of distal femoral cortical defects.

نویسندگان

  • Derek F Amanatullah
  • Joel C Williams
  • David P Fyhrie
  • Robert M Tamurian
چکیده

The optimal management of pathologic long bone lesions remains a challenge in orthopedic surgery. The goal of the current study was to investigate the effect of defect depth on the torsional properties of the distal femur. A laterally placed distal metaphyseal cylindrical defect was milled in the cortex of the distal femur in 20 composite models. The proximal extent of the defects was constant. By decreasing the radius of the cylinder that intersected this predefined cord, 4 different radii defining 4 different depths of resection of the distal femur were created for testing: 17%, 33%, 50%, and 67% cortical defects, when normalized to the width of the femur at the level of resection. Each femur was mounted into a hydraulic axial/torsion materials testing machine and each specimen underwent torsional stiffness testing and torsional failure in external rotation. The specimens with less than a 33% cortical loss consistently demonstrated a superiorly oriented spiral fracture pattern, while the specimens with greater than a 50% cortical loss consistently demonstrated an inferiorly oriented transverse fracture pattern. The cortical defects were all statistically (P<.05) less stiff in torsion as the defect grew larger. There was a strong linear correlation between the mean torsional stiffness and cortical defect size (r(2)=0.977). This observation is supported by finite element analysis. The amount of femur remaining is crucial to stability. This biomechanical analysis predicts a critical loss of torsional integrity when a cortical defect approaches 50% of the width of the femur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Risk of periprosthetic femur fracture after anterior cortical bone windowing

BACKGROUND AND PURPOSE Removal of distal cement at femoral implant revision is technically challenging and is associated with complications such as cortical perforations. A technique that can reduce the risks and operating time is to make a small cortical window in the distal femur for enhanced access. We wanted to determine whether the use of long, bridging, cemented femoral stems is necessary...

متن کامل

Partial Resurfacing of the Distal Femoral Cartilage Defect with Stem Cell- Seeded Poly-Vinyl-Alcohol (PVA) Scaffold

Objective- To evaluate the biological compatibility of differentiated stem cells embedded in poly-vinyl-alcohol (PVA) scaffolds for repair of distal femoral cartilage defect.   Design- Experimental in vivo study. Animals- Twelve adult male New Zealand white rabbits were used which were divided into two groups (I, II) six rabbits each.   Procedures- Mesenchymal stem cells were isolated from h...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Prediction of Pathological Fracture of the Femoral Shaft with osteolytic lesion using a CT-Based Nonlinear 3-Dimensional Finite Element Method Estimation of Torsional Strength

Nonlinear 3-Dimensional Finite Element Method –Estimation of Torsional Strength Chiba, D; +Sano, H; Kishimoto, K N; Takahashi, A; Nakajo S; Hatori M; Itoi, E +Tohoku University, Sendai, Japan; Nakajo Orthopaedic Clinic [email protected] INTRODUCTION: It is known that metastatic bone lesions often represent osteolytic changes, which reduce bone strength and eventually lead to fractur...

متن کامل

Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis

BACKGROUND Proximal femoral bone loss during revision hip arthroplasty often requires bypassing the deficient metaphyseal bone to obtain distal fixation. The purpose of this study was to determine the effect of stem diameter and length of diaphyseal contact in achieving rotational stability in revision total hip arthroplasty. METHODS Twenty-four cadaveric femoral specimens were implanted with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2014