Re-inspiration of CO2 from ventilator circuit: effects of circuit flushing and aspiration of dead space up to high respiratory rate

نویسندگان

  • Edoardo De Robertis
  • Leif Uttman
  • Björn Jonson
چکیده

INTRODUCTION Dead space negatively influences carbon dioxide (CO(2)) elimination, particularly at high respiratory rates (RR) used at low tidal volume ventilation in acute respiratory distress syndrome (ARDS). Aspiration of dead space (ASPIDS), a known method for dead space reduction, comprises two mechanisms activated during late expiration: aspiration of gas from the tip of the tracheal tube and gas injection through the inspiratory line - circuit flushing. The objective was to study the efficiency of circuit flushing alone and of ASPIDS at wide combinations of RR and tidal volume (V(T)) in anaesthetized pigs. The hypothesis was tested that circuit flushing and ASPIDS are particularly efficient at high RR. METHODS In Part 1 of the study, RR and V(T) were, with a computer-controlled ventilator, modified for one breath at a time without changing minute ventilation. Proximal dead space in a y-piece and ventilator tubing (VD(aw, prox)) was measured. In part two, changes in CO(2) partial pressure (PaCO(2)) during prolonged periods of circuit flushing and ASPIDS were studied at RR 20, 40 and 60 minutes(-1). RESULTS In Part 1, VDaw, prox was 7.6 +/- 0.5% of V(T) at RR 10 minutes(-1) and 16 +/- 2.5% at RR 60 minutes(-1). In Part 2, circuit flushing reduced PaCO(2) by 20% at RR 40 minutes(-1) and by 26% at RR 60 minutes(-1). ASPIDS reduced PaCO(2) by 33% at RR 40 minutes(-1) and by 41% at RR 60 minutes(-1). CONCLUSIONS At high RR, re-breathing of CO(2) from the y-piece and tubing becomes important. Circuit flushing and ASPIDS, which significantly reduce tubing dead space and PaCO2, merit further clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effects of apparatus dead space on P(aCO2) in patients receiving lung-protective ventilation.

BACKGROUND Lung-protective ventilation using tidal volume (V(T)) of 4-6 mL/kg (predicted body weight) reduces mortality (compared with traditional V(T)) in patients with acute respiratory distress syndrome and acute lung injury. Standardized use of lower V(T) can result in respiratory acidosis and has raised new concerns about the appropriate configuration of the ventilator circuit, especially ...

متن کامل

Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate.

BACKGROUND The reduction of instrumental dead space is a recognized approach to preventing ventilation-induced lung injury in premature infants. However, there are no published data regarding the effectiveness of instrumental dead-space reduction in endotracheal tube (ETT) connectors. We tested the impact of the Y-piece/ETT connector pairs with reduced instrumental dead space on CO2 elimination...

متن کامل

Carbon dioxide entrainment during high-frequency oscillatory ventilation: a model analysis.

High-frequency ventilation got its start in the United States from a paper by Dr Mirosolav Klain, an anesthesiologist who described a high-frequency jet ventilator (HFJV)1 he built using a fluidic control circuit purchased as a demonstration kit from Corning Glass Works.2 Based on his description of the circuit, we built an HFJV and humidification system that we used to ventilate neonates clini...

متن کامل

Investigating Characteristics of N2, CO2 and CF3I in Contrast to High Current Arcs in Circuit Breakers to Choose a Suitable Substitute for SF6

Specific and sensitive operation of circuit breakers makes an individual position for them in power networks. Circuit breakers are at the central gravity of variations and execution operations. Therefore, an optimum operation is the main reason to investigate about new gases to be used in MV and HV circuit breakers instead of SF6. The arc process has enormous complexity because of hydrodynamic ...

متن کامل

Ventilator with a capnograph smart sensors

Today, the world has witnessed increasing development in various fields, including industry and medicine. One of the best ways to achieve these objectives is the integration of different sciences including electronics, robotics and medicine. Ventilator set that provides respiratory function for patients get smarter and more capable than older generations, during mechanical ventilation to preven...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2010