Measurement of Dielectric Properties at 75 - 325 GHz using a Vector Network Analyzer and Full Wave Simulator

نویسندگان

  • Subash KHANAL
  • Tero KIURU
  • Juha MALLAT
  • Olli LUUKKONEN
  • Antti V. RÄISÄNEN
چکیده

This paper presents a fast and easy to use method to determine permittivity and loss tangent in the frequency range of 75 to 325 GHz. To obtain the permittivity and the loss tangent of the test material, the reflection and transmission S-parameters of a waveguide section filled with the test material are measured using a vector network analyzer and then compared with the simulated plots from a full wave simulator (HFSS), or alternatively the measurement results are used in mathematical formulas. The results are coherent over multiple waveguide bands.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Radar Absorbing Nanocomposites Based on Co-ferrite/Nano Carbon/polymeric epoxy resin

In this research work cobalt-ferrite (CoFe2O4) nanoparticles were synthesized by a simple, general sol-gel auto-combustion method. For this study, electromagnetic (EM) wave absorbing coatings with different weight fractions of nano-carbon and CoFe2O4 (which, arises from both dielectric and magnetic contributions) and polymeric epoxy resin were prepared and their characteristics were fully inves...

متن کامل

Highly Selective Lowpass Filter with Wide Stopband in Suspended Stripline Technology for Millimeter-wave Diplexer Applications

This paper presents a low loss and high selective lowpass filter which is implemented using suspended stripline (SSL) technology. The proposed structure is comprised of a 13th order generalized Chebyshev lowpass filter which enjoys integrated waveguide-to-SSL transitions. This filter is designed and fabricated to be used as lowpass channel of a U-band diplexer employed in frontend of a U-band d...

متن کامل

Low-cost Vector Network Analyzer for Biomedical Applications

A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...

متن کامل

Nondestructive and Noncontact Dielectric Measurement Methods for Transformer Oil Using Free-space Microwave Measurement System in 19 – 25 GHz Frequency Range

Nondestructive, noncontact and real time evaluation of dielectric properties of low-loss liquids are important for applications such as service-aged transformer oil, biomedical, remote sensing and design of radar absorbing material. Free-space methods were developed to measure dielectric properties of low-loss liquids at microwave frequencies. Metal-back method was developed for Freespace Micro...

متن کامل

Simple Method for the Preparation of Fe3O4/MWCNT Nanohybrid as Radar Absorbing Material (RAM)

We have successfully prepared Fe3O4/MWCNT nanohybrid with a very simple and economical method. Multi-Walled Carbon NanoTubes (MWCNT) encapsulated with Fe3O4 nanoparticles were synthesized via pyrolyzing of ferrocene. The sample was characterized with XRD, TEM and Vibrating Sample Magnetometer (VSM). Also, Permeability (µ) and Permittivity (ε) were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012