Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements.

نویسندگان

  • Jose M Martinez-de-la-Casa
  • Julian Garcia-Feijoo
  • Ana Fernandez-Vidal
  • Carmen Mendez-Hernandez
  • Julian Garcia-Sanchez
چکیده

PURPOSE To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central corneal thickness (CCT) was measured by ultrasound pachymetry. RESULTS ORA readings were consistently higher than GAT measurements (Goldmann-correlated IOP - IOP GAT mean difference, 7.2 +/- 3.5 mm Hg; corneal-compensated IOP - IOP GAT mean difference, 8.3 +/- 4.0 mm Hg) However, differences were not constant and increased with increasing IOP GAT readings, both with respect to Goldmann-correlated IOP (slope = 0.623, P < 0.0001) and corneal-compensated IOP (slope = 0.538, P < 0.0001). Both pressure measurements provided by the ORA showed significant correlation with CCT (CCT versus Goldmann-correlated IOP: r = 0.460, P = 0.001; CCT versus corneal-compensated IOP: r = 0.442, P = 0.001). No significant effects of corneal curvature or refraction on any of the pressures were observed. CONCLUSIONS The ORA significantly overestimates IOP compared with the GAT. Differences between both sets of measures increase as the GAT-determined IOP increases. ORA readings seem to be affected by central corneal thickness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Goldmann applanation tonometry versus ocular response analyzer for intraocular pressure measurements in keratoconic eyes.

PURPOSE To compare intraocular pressure (IOP) measurements obtained with the Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) in patients with keratoconus (KC) and analyze their dependence on ocular anatomic parameters. METHODS Patients with KC were recruited prospectively. IOP was measured using GAT and ORA. The ORA provided a Goldmann correlated IOP (IOPg) and a c...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

متن کامل

CLINICAL SCIENCE Can We Measure Corneal Biomechanical Changes After Collagen Cross-Linking in Eyes With Keratoconus?—A Pilot Study

Methods: Ten eyes of 10 patients aged 26.5 6 5.7 (mean 6 SD) years with progressive keratoconus were treated with UV-A– riboflavin CXL and assessed with the Ocular Response Analyzer (ORA) that measured corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal compensated intraocular pressure (IOPcc). Intraocular pressure was also meas...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Tonographic Effect of Ocular Response Analyzer in Comparison to Goldmann Applanation Tonometry

AIMS The tonographic effect is a phenomenon of intraocular pressure (IOP) reduction following repeated tonometry. This study examines whether the tonographic effect occurs following IOP measurement performed with Ocular Response Analyzer (ORA). METHODS Both eyes of 31 glaucoma patients and 35 healthy controls underwent nine IOP-measurements performed with GAT and ORA. The number of GAT and OR...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 47 10  شماره 

صفحات  -

تاریخ انتشار 2006