THE RELATIVE SUSCEPTIBILITY OF ANIMALS AND HUMANS TO THE CARCINOGENIC HAZARD POSED BY EXPOSURE TO 2,3,7,&TCDD: AN ANALYSIS USING STANDARD AND INTERNAL MEASURES OF DOSE Scan M. Hays”, Less

نویسندگان

  • L. Aylward
  • Nathan J. Karch
  • Dennis J. Paustenbach
چکیده

An analysis of the carcinogenic dose-response for 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) in humans and animals was performed based on measured tissue and serum concentrations and using alternatives to administered dose as the dosimetric. The TCDD-related carcinogenic response in rats (female rat liver tumors from Kociba et al. [l], using revised pathology from Goodman and Sauer, [2]) was compared to that in humans (lung cancer rates in Fingerhut et al., [3]). Three dosimetries were used: serum lipid TCDD area-under-the-curve (AUC), peak serum lipid concentration (C,,) and average serum lipid concentration (C,,). Rat serum concentration-time profiles were estimated based on measured adipose lipid TCDD concentrations at the end of the Kociba et al. [I] bioassay, assuming first-order elimination and a half-life of 25 days. Human concentration-time profiles were estimated based on measured serum lipid TCDD concentrations and known dates of first and last exposure, with an assumed 7.5 year half-life and first-order elimination. Comparison of rat and human responses indicated that, using all three of these dosimetries, humans are much less sensitive than rats to the carcinogenic effects of TCDD. Regardless of the dosimetric chosen, the cancer mortality in humans in the NIOSH cohort, if due to TCDD, is relatively insensitive to dose as defined in Fingerhut et al., [3]. Our analysis indicates that human exposure to background levels of TCDD (about 5 ppt serum lipid concentration) is not likely to produce an incremental cancer risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple liquid chromatography-tandem mass spectrometry method to determine relative plasma exposures of drug metabolites across species for metabolite safety assessments.

Recent regulatory guidance suggests that metabolites identified in human plasma should be present at equal or greater levels in one of the animal species used in safety assessments. In this report, a high-performance liquid chromatography-tandem mass spectrometry method is described whereby quantitative comparisons of exposures to metabolites between species can be obtained in the absence of au...

متن کامل

Short Communication Covalent Binding of 2-Amino-3,8-dimethylimidazo[4,5-f]quinoxaline to Albumin and Hemoglobin at Environmentally Relevant Doses Comparison of Human Subjects and F344 Rats

Covalent binding of the food-borne heterocyclic amine 2-amino3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) to albumin and hemoglobin (Hb), 3.5–6.0 hr after oral administration of a single dose of either 21.3 or 228.0 mg of [C]MeIQx (304 and 3257 ng/kg of body weight, respectively, based on a 70-kg subject weight), was studied in human volunteers using accelerator mass spectrometry. Human protei...

متن کامل

Short Communication Covalent Binding of 2-Amino-3,8-dimethylimidazo[4,5-f]quinoxaline to Albumin and Hemoglobin at Environmentally Relevant Doses Comparison of Human Subjects and F344 Rats

Covalent binding of the food-borne heterocyclic amine 2-amino3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) to albumin and hemoglobin (Hb), 3.5–6.0 hr after oral administration of a single dose of either 21.3 or 228.0 mg of [C]MeIQx (304 and 3257 ng/kg of body weight, respectively, based on a 70-kg subject weight), was studied in human volunteers using accelerator mass spectrometry. Human protei...

متن کامل

Quantitation of soybean allergens using tandem mass spectrometry.

Soybean (Glycine max) seed contain some proteins that are allergenic to humans and animals. However, the concentration of these allergens and their expression variability among germplasms is presently unknown. To address this problem, 10 allergens were quantified from 20 nongenetically modified commercial soybean varieties using parallel, label-free mass spectrometry approaches. Relative quanti...

متن کامل

New Highly-Sensitive Ultra-Performance Liquid Chromatography - Mass Spectrometry Method for Quantification of Telmisartan in Human Plasma

Purpose: To develop and validate a simple, rapid, sensitive and specific ultraperformance liquid chromatography mass spectrometry method for the quantification of the angiotensin II receptor antagonist, telmisartan (TEL), in human plasma. Methods: After simple protein precipitation using acetonitrile and methanol, TEL and internal standard (IS) abiraterone were separated on Acquity UPLC BEH C18...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003