An automated "high-pressure" liquid-chromatographic assay for hemoglobin A1c.
نویسندگان
چکیده
An automated "high-pressure" liquid-chromatographic assay for hemoglobin A1c is described. We use a 45-min incubation in acetate buffer (pH 5.5) to eliminate labile glycated hemoglobins. In this automated system conventional modules are used but it incorporates a solvent-switching valve to select either of two buffers, which differ in pH and NaCl concentration. The chromatographic column contains "polyCAT" (a weak cation-exchanger, polyaspartic acid linked to silica). Run time is 14 min per sample. The method is precise and results correlate well with those by other ion-exchange procedures.
منابع مشابه
Quantitation of hemoglobin A1a+b and hemoglobin A1c by automated "high-performance" liquid chromatography.
The glycosylated hemoglobins A1a+b and A1c have been rapidly and precisely quantitated in 5-micro L samples of human blood hemolysate (approximately 240 micrograms of hemoglobin) by cation-exchange column chromatography. Total chromatographic is 22.0 min. Proportions of Hb A1c range from 3.85 to 6.71% in normal individuals and from 4.23 to 19.90% in diabetic subjects. Within-day variation was 1...
متن کاملMeasurement of hemoglobin A1c by a new liquid-chromatographic assay: methodology, clinical utility, and relation to glucose tolerance evaluated.
A chromatographic method for determining glycated hemoglobin (Hb A1c) by use of a new monodisperse cation-exchanger has been investigated. Hb A1c was separated from other "minor hemoglobins": Hb F, Hb A3 (the glutathione adduct), and the acetaldehyde adduct in alcoholics. The method was fully automated and a single column could be used for more than 1000 runs. The normal reference interval was ...
متن کاملComparative evaluation of three assay systems for automated determination of hemoglobin A1c.
We evaluated three newly introduced systems for automated determinations of hemoglobin (Hb) A1c, which allow the processing of large amounts of samples in a routine clinical laboratory. We compared these methods--the Variant HPLC, the Hi-Auto A1c analyzer system, and the Roche immunoassay--with the Diamat HPLC system. All showed good precision and good concordance with the Diamat HPLC. The refe...
متن کاملAffinity binding assay of glycohemoglobin by two-dimensional centrifugation referenced to hemoglobin A1c.
We describe an automated assay of glycohemoglobin performed with the Abbott Vision analyzer. The assay is based on batch affinity-extraction with 3-aminophenylboronic acid-derivatized agarose beads. Reagents are packaged in a disposable test pack. Whole-blood specimens are hemolyzed with saponin within a glass capillary tube inserted into the test pack. The sample is automatically diluted with,...
متن کاملEvaluation of a nucleic acid-based cross-linking assay to screen for hereditary hemochromatosis in healthy blood donors.
14. 13. Chung BH, Segrest JP, Ray MJ, Brunzell JD, Hokanson JE, Krauss RM, et al. Single vertical spin density gradient ultracentrifugation. Methods Enzymol 1986;128:181–209. 14. Khuu HM, Robinson CA, Goolsby K, Hardy RW, Konrad RJ. Evaluation of a fully automated high-performance liquid chromatography assay for hemoglobin A1c. Arch Pathol Lab Med 1999;123:763–7. 15. Khuu HM, Robinson CA, Briss...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 11 شماره
صفحات -
تاریخ انتشار 1984