Principles of Tscherning aberrometry.

نویسندگان

  • M Mrochen
  • M Kaemmerer
  • P Mierdel
  • H E Krinke
  • T Seiler
چکیده

Higher-order optical errors of the human eye are often responsible for reduced visual acuity in spite of an optimal spherical or cylindrical refraction. These optical aberrations are of natural origin or can result from operations on the eye involving optical structures. The presented wavefront analyzer is based on Tscherning's aberroscope. A collimated laser beam illuminates a mask with regular matrix pin holes which forms a bundle of thin parallel rays. These rays form a retinal spot pattern on the retina that is more or less distorted according to the optical errors of the eye. This retinal spot pattern is imaged onto the sensor of a low-light CCD camera by indirect ophthalmoscopy. The deviations of all spots from their ideal regular positions are measured by means of a personal computer, and from these values the optical aberrations are computed in the form of Zernike polynomials up to the 8th order.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Corneal Aberrometry Parameters Before and After Cross-Linking in Patients with Keratoconus

Background and Objective: In the last decade, cross-linking (CXL) has been widely used for treating people with progressive keratoconus. The present study aimed to compare corneal aberrometry parameters before and after CXL in patients with keratoconus. Materials and Methods: In this cross-sectional study, 67 patients with keratoconus referred to Farshchian Sina Medical Education Center, Hamad...

متن کامل

Principles of ray tracing aberrometry.

PURPOSE Of all transforms of an eye, aberrations are significant when higher visual acuity is to be achieved. Ray tracing aberrometry developed by the Institute of Biomedical Engineering (Kiev) and first tested at the Vardinoyannion Eye Institute of Crete is a promising technique for eye refraction aberration and refraction mapping. METHODS The technique uses measurement of the position of a ...

متن کامل

Comparison of sorting algorithms to increase the range of Hartmann-Shack aberrometry.

Recently many software-based approaches have been suggested for improving the range and accuracy of Hartmann-Shack aberrometry. We compare the performance of four representative algorithms, with a focus on aberrometry for the human eye. Algorithms vary in complexity from the simplistic traditional approach to iterative spline extrapolation based on prior spot measurements. Range is assessed for...

متن کامل

Principles of Hartmann-Shack aberrometry.

RAY OPTICS DESCRIPTION Nearly 400 years ago, the celebrated Jesuit philosopher-astronomer, Christopher Scheiner, professor at the University of Ingolstadt, demonstrated the focusing ability of the human eye using a simple device known as the Scheiner Disk.1 Scheiner's experiments showed that if an optically imperfect eye views through an opaque disk perforated with two pinholes, a single distan...

متن کامل

On the Discovery of Monocular Rivalry by Tscherning in 1898: Translation and Review

Monocular rivalry was named by Breese in 1899. He made prolonged observation of superimposed orthogonal gratings; they fluctuated in clarity with either one or the other grating occasionally being visible alone. A year earlier, Tscherning observed similar fluctuations with a grid of vertical and horizontal lines and with other stimuli; we draw attention to his prior account. Monocular rivalry h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2000