Gram-negative rod contamination of an Ohmeda anesthesia machine.

نویسندگان

  • S C Body
  • J H Philip
چکیده

To the Editor:—During the preoperative check of an Ohmeda Modulus SE anesthesia machine (Ohmeda Inc., Madison, WI) with an Ohmeda 7900 ventilator and expiratory limb water trap, we observed approximately 1 cm (4 ml) of water in the base of the water trap. On examination, the water appeared to be very pale orange in appearance but did not have an obvious odor. Culture of this fluid grew . 10/ml nonfermenting Gram-negative rods, possibly Flavobacterium or a Pseudomonas species. Flavobacterium species are responsible for human neonatal meningitis and in-dwelling line infection in immunocompromised hosts. The role of Pseudomonas in human infection is well known. Subsequently, small amounts (, 5 mm depth) of fluid were observed in two identical anesthesia machines over the following 3 days. Both fluid cultures grew . 10/ml nonfermenting Gram-negative rods. No further identification of organisms was undertaken. Aerobic and anaerobic swabs of the inspiratory and expiratory ports of the soda-lime absorber had no growth at 5 days. This observation is in contrast to that of Azzam et al., who observed no contamination over a 94-day period in a single Ohmeda water trap that underwent routine cleaning and drainage. However, the Ohmeda water trap is capable of storing fluid over a long period of time, unless regular cleaning is undertaken. The expiratory limb of respiratory apparatus is capable of considerable contamination by respiratory organisms, especially Pseudomonas aeruginosa. Insufficient drying has been implicated as a contributing factor in cross-patient infection. The Ohmeda water trap installation instructions state that the trap should be cleaned in a neutral detergent but do not contain specific information on the frequency of such cleaning. No regular cleaning had been advised, or undertaken, at our institution over the approximately 18-month period of use. There had been no clinically obvious increase in pulmonary infections associated with those operating rooms during that period, but no formal qualityassurance process for review of pulmonary infections existed. Whether anesthesia machines are a source of nosocomial infection is still open to debate. The soda-lime canister seems to be a somewhat effective filter (60 –99.9%) for most organisms, except perhaps Mycobacterium tuberculosis and at low fresh gas flows. Our routine practice was to use disposable circle anesthesia circuits but not bacteriologic filters. Subsequently, a regular (daily) cleaning program had been instituted. We have elected not to use bacteriologic filters routinely in the circuits of these anesthesia machines because, although they are effective filters, their efficacy in reducing patient cross-infection is unproven. Other institutions may wish to examine their own institutional practices in light of this observation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial growth on the anesthesia machine.

The purpose of this study was to determine the amount of microbial growth that develops on the anesthesia machine after a full day's use in the operating room. This descriptive bacteriology study is relevant to anesthesia practice because of the proximity of the oropharynx and multiple body fluids to anesthesia equipment and the potential for cross-contamination to patients and staff. The Wilco...

متن کامل

Comparison of tests for detecting leaks in the low-pressure system of anesthesia gas machines.

Small leaks in the low-pressure system (LPS) of the anesthesia gas machine can cause hypoxia or patient awareness. We sought to determine the relative sensitivities of the various tests recommended for detecting LPS leaks before anesthesia. Special adapters were fashioned to create leaks of six different sizes in the LPS that were equivalent to the following: a single 25-, 22-, 20-, or 15-gauge...

متن کامل

The effect of a bellows leak in an Ohmeda 7810 ventilator on room contamination, inspired oxygen, airway pressure, and tidal volume.

We investigated the effect of a small bellows leak (bellows full at end-expiration) on inspired oxygen fraction (Fio(2)), exhaled tidal volume (Vt), airway pressure, and room contamination in an oxygen-driven anesthesia ventilator (Ohmeda 7810, Madison, WI). CO(2) concentration at the ventilator exhalation valve, Fio(2), Vt, and airway pressure were measured (n = 3) while ventilating a CO(2)-pr...

متن کامل

A field-expedient Ohmeda Universal Portable Anesthesia Complete draw-over vaporizer setup.

The Ohmeda Universal Portable Anesthesia Complete (U-PAC) draw-over anesthetic system is active in the US Army inventory. It is standard equipment for Certified Registered Nurse Anesthetists assigned to US Army Forward Surgical Teams and Joint Special Operations Command. The purpose of this article is to describe a practical and field-expedient U-PAC draw-over vaporizer setup used during Operat...

متن کامل

Improved system for floor cleaning in health care facilities.

A new system has been developed for sanitizing floors in hospitals; this system replaces the traditional procedure of daily dusting and wet mopping with a disinfectant-detergent solution and periodic buffing . This new system relies on a sequence of procedures consisting of dust mopping using a chemically treated dust mop, machine buffing of a sprayed-on polymer treatment, and a second dust mop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2000