Improved access and visibility during stapling of the ultra-low rectum: a comparative human cadaver study between two curved staplers

نویسندگان

  • David E Rivadeneira
  • Juan Carlos Verdeja
  • Toyooki Sonoda
چکیده

UNLABELLED BACKGROUND The purpose of this study was to compare in human cadavers the applicability of a commonly used stapling device, the CONTOUR® curved cutter (CC) (Ethicon Endo-Surgery, Cincinnati, OH) to a newly released, curved stapler, the Endo GIA™ Radial Reload with Tri-Staple™ Technology (RR) (Covidien, New Haven, CT) METHODS: Four experienced surgeons performed deep pelvic dissection with total mesorectal excision (TME) of the rectum in twelve randomized male cadavers. Both stapling devices were applied to the ultra-low rectum in coronal and sagittal configurations. Extensive measurements were recorded of anatomic landmarks for each cadaver pelvis along with various aspects of access, visibility, and ease of placement for each device. RESULTS The RR reached significantly lower into the pelvis in both the coronal and sagittal positions compared to the CC. The median distance from the pelvic floor was 1.0 cm compared to 2.0 cm in the coronal position, and 1.0 cm versus 3.3 cm placed sagitally, p < 0.0001. Surgeons gave a higher visibility rating with less visual impediment in the sagittal plane using the RR Stapler. Impediment of visibility occurred in only 10% (5/48) of RR applications in the coronal position, compared to a rate of 48% (23/48) using the CC, p = 0.0002. CONCLUSIONS The RR device performed significantly better when compared to the CC stapler in regards to placing the stapler further into the deep pelvis and closer to the pelvic floor, while causing less obstructing of visualization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stapler access and visibility in the deep pelvis: A comparative human cadaver study between a computerized right angle linear cutter versus a curved cutting stapler

PURPOSE Distal rectal stapling is often challenging because of limited space and visibility. We compared two stapling devices in the distal rectum in a cadaver study: the iDrive™ right angle linear cutter (RALC) (Covidien, New Haven, CT) and the CONTOUR® curved cutter (CC) (Ethicon Endo-Surgery, Cincinnati, OH). METHODS Twelve male cadavers underwent pelvic dissection by 4 surgeons. After rec...

متن کامل

Retrospective analysis of rectal stenosis after anterior resections with or without stapling: rectal stapling is not a “thornless rosary”

Recently, stapler anastomosis is the method of choice in low or ultra low resection for rectal carcinoma. In this study, risk of rectal stricture formation after double stapling colorectal anastomosis was evaluated. We here with presented an invitro investigation and a retrospective analysis of 91 cases of rectal carcinoma treated by low or ultra low anterior resection with hand-sewn or double-...

متن کامل

Treatment of Colorectal Stricture After Circular Stapling Anastomoses

Performing an end-to-end low rectal anastomosis with the linear single stapling technique was first reported in 1979 (Ravitch & Steichen, 1979). An improved circular stapling technique for anterior resection of the rectum, i.e. double stapling technique, overcoming the problems of insertion of the purse-string on the rectum stump and of disparity in size between the rectum and colon was introdu...

متن کامل

Pii: S1010-7940(02)00101-x

Background: There is little information available regarding the relative advantage of stapling over ligation for major pulmonary vessels in lung resection. The thin and fragile structure of pulmonary vascular walls for their large luminal size might have made surgeons reluctant to use staplers. This study was intended to demonstrate the feasibility of pulmonary vascular division by staplers. Me...

متن کامل

Adverse events of lung tissue stapling in thoracic surgery.

PURPOSE The use of staplers for thoracic surgery has been regarded as a safe procedure though sometimes adverse events (AEs) of stapling are experienced. The aim of this study is to analyze AEs of lung tissue stapling. METHODS A retrospective multi-institutional review was conducted by 27 institutions of the Central Japan Lung Cancer Surgery Study Group. During the research period, lung tissu...

متن کامل