123I-Mibg scintigraphy and 18F-Fdg-Pet imaging for diagnosing neuroblastoma

نویسندگان

  • Gitta Bleeker
  • Godelieve Am Tytgat
  • Judit A Adam
  • Huib N Caron
  • Leontien Cm Kremer
  • Lotty Hooft
  • Elvira C van Dalen
چکیده

BACKGROUND Neuroblastoma is an embryonic tumour of childhood that originates in the neural crest. It is the second most common extracranial malignant solid tumour of childhood.Neuroblastoma cells have the unique capacity to accumulate Iodine-123-metaiodobenzylguanidine (¹²³I-MIBG), which can be used for imaging the tumour. Moreover, ¹²³I-MIBG scintigraphy is not only important for the diagnosis of neuroblastoma, but also for staging and localization of skeletal lesions. If these are present, MIBG follow-up scans are used to assess the patient's response to therapy. However, the sensitivity and specificity of ¹²³I-MIBG scintigraphy to detect neuroblastoma varies according to the literature.Prognosis, treatment and response to therapy of patients with neuroblastoma are currently based on extension scoring of ¹²³I-MIBG scans. Due to its clinical use and importance, it is necessary to determine the exact diagnostic accuracy of ¹²³I-MIBG scintigraphy. In case the tumour is not MIBG avid, fluorine-18-fluorodeoxy-glucose ((18)F-FDG) positron emission tomography (PET) is often used and the diagnostic accuracy of this test should also be assessed. OBJECTIVES PRIMARY OBJECTIVES 1.1 To determine the diagnostic accuracy of ¹²³I-MIBG (single photon emission computed tomography (SPECT), with or without computed tomography (CT)) scintigraphy for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old.1.2 To determine the diagnostic accuracy of negative ¹²³I-MIBG scintigraphy in combination with (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old, i.e. an add-on test. SECONDARY OBJECTIVES 2.1 To determine the diagnostic accuracy of (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old.2.2 To compare the diagnostic accuracy of ¹²³I-MIBG (SPECT-CT) and (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma and its metastases at first diagnosis or at recurrence in children from 0 to 18 years old. This was performed within and between included studies. ¹²³I-MIBG (SPECT-CT) scintigraphy was the comparator test in this case. SEARCH METHODS We searched the databases of MEDLINE/PubMed (1945 to 11 September 2012) and EMBASE/Ovid (1980 to 11 September 2012) for potentially relevant articles. Also we checked the reference lists of relevant articles and review articles, scanned conference proceedings and searched for unpublished studies by contacting researchers involved in this area. SELECTION CRITERIA We included studies of a cross-sectional design or cases series of proven neuroblastoma, either retrospective or prospective, if they compared the results of ¹²³I-MIBG (SPECT-CT) scintigraphy or (18)F-FDG-PET(-CT) imaging, or both, with the reference standards or with each other. Studies had to be primary diagnostic and report on children aged between 0 to 18 years old with a neuroblastoma of any stage at first diagnosis or at recurrence. DATA COLLECTION AND ANALYSIS One review author performed the initial screening of identified references. Two review authors independently performed the study selection, extracted data and assessed the methodological quality.We used data from two-by-two tables, describing at least the number of patients with a true positive test and the number of patients with a false negative test, to calculate the sensitivity, and if possible, the specificity for each included study.If possible, we generated forest plots showing estimates of sensitivity and specificity together with 95% confidence intervals. MAIN RESULTS Eleven studies met the inclusion criteria. Ten studies reported data on patient level: the scan was positive or negative. One study reported on all single lesions (lesion level). The sensitivity of ¹²³I-MIBG (SPECT-CT) scintigraphy (objective 1.1), determined in 608 of 621 eligible patients included in the 11 studies, varied from 67% to 100%. One study, that reported on a lesion level, provided data to calculate the specificity: 68% in 115 lesions in 22 patients. The sensitivity of ¹²³I-MIBG scintigraphy for detecting metastases separately from the primary tumour in patients with all neuroblastoma stages ranged from 79% to 100% in three studies and the specificity ranged from 33% to 89% for two of these studies.One study reported on the diagnostic accuracy of (18)F-FDG-PET(-CT) imaging (add-on test) in patients with negative ¹²³I-MIBG scintigraphy (objective 1.2). Two of the 24 eligible patients with proven neuroblastoma had a negative ¹²³I-MIBG scan and a positive (18)F-FDG-PET(-CT) scan.The sensitivity of (18)F-FDG-PET(-CT) imaging as a single diagnostic test (objective 2.1) and compared to ¹²³I-MIBG (SPECT-CT) (objective 2.2) was only reported in one study. The sensitivity of (18)F-FDG-PET(-CT) imaging was 100% versus 92% of ¹²³I-MIBG (SPECT-CT) scintigraphy. We could not calculate the specificity for both modalities. AUTHORS' CONCLUSIONS The reported sensitivities of ¹²³-I MIBG scintigraphy for the detection of neuroblastoma and its metastases ranged from 67 to 100% in patients with histologically proven neuroblastoma.Only one study in this review reported on false positive findings. It is important to keep in mind that false positive findings can occur. For example, physiological uptake should be ruled out, by using SPECT-CT scans, although more research is needed before definitive conclusions can be made.As described both in the literature and in this review, in about 10% of the patients with histologically proven neuroblastoma the tumour does not accumulate ¹²³I-MIBG (false negative results). For these patients, it is advisable to perform an additional test for staging and assess response to therapy. Additional tests might for example be (18)F-FDG-PET(-CT), but to be certain of its clinical value, more evidence is needed.The diagnostic accuracy of (18)F-FDG-PET(-CT) imaging in case of a negative ¹²³I-MIBG scintigraphy could not be calculated, because only very limited data were available. Also the detection of the diagnostic accuracy of index test (18)F-FDG-PET(-CT) imaging for detecting a neuroblastoma tumour and its metastases, and to compare this to comparator test ¹²³I-MIBG (SPECT-CT) scintigraphy, could not be calculated because of the limited available data at time of this search.At the start of this project, we did not expect to find only very limited data on specificity. We now consider it would have been more appropriate to use the term "the sensitivity to assess the presence of neuroblastoma" instead of "diagnostic accuracy" for the objectives.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional Imaging of Neuroendocrine Tumors: A Head-to-Head Comparison of Somatostatin Receptor Scintigraphy,

Functional techniques are playing a pivotal role in the imaging of cancer today. Our aim was to compare, on a head-to-head basis, 3 functional imaging techniques in patients with histologically verified neuroendocrine tumors: somatostatin receptor scintigraphy (SRS) with 111In-diethylenetriaminepentaacetic acidoctreotide, scintigraphy with 123I-metaiodobenzylguanidine (MIBG), and 18F-FDG PET. M...

متن کامل

123I-MIBG scintigraphy and 18F-FDG PET in neuroblastoma.

UNLABELLED The purpose of this study was to compare the diagnostic utility of (123)I-metaiodobenzylguanidine ((123)I-MIBG) scintigraphy and (18)F-FDG PET in neuroblastoma. METHODS A total of 113 paired (123)I-MIBG and (18)F-FDG PET scans in 60 patients with neuroblastoma were retrospectively reviewed. Paired scans were acquired within 14 days of each other. RESULTS For stage 1 and 2 neurobl...

متن کامل

Clinical experience with 18F-fluorodeoxyglucose positron emission tomography and 123I-metaiodobenzylguanine scintigraphy in pediatric neuroblastoma: complementary roles in follow-up of patients

PURPOSE To evaluate the potential utility of (123)I-metaiodobenzylguanine ((123)I-MIBG) scintigraphy and (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) for the detection of primary and metastatic lesions in pediatric neuroblastoma (NBL) patients, and to determine whether (18)F-FDG PET is as beneficial as (123)I-MIBG imaging. METHODS We selected 8 NBL patients with sig...

متن کامل

Functional imaging of neuroendocrine tumors: a head-to-head comparison of somatostatin receptor scintigraphy, 123I-MIBG scintigraphy, and 18F-FDG PET.

UNLABELLED Functional techniques are playing a pivotal role in the imaging of cancer today. Our aim was to compare, on a head-to-head basis, 3 functional imaging techniques in patients with histologically verified neuroendocrine tumors: somatostatin receptor scintigraphy (SRS) with (111)In-diethylenetriaminepentaacetic acid-octreotide, scintigraphy with (123)I-metaiodobenzylguanidine (MIBG), an...

متن کامل

Uptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease

Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2015