Influence of adjacent low-dose fields on tolerance to high doses of protons in rat cervical spinal cord.

نویسندگان

  • Hendrik P Bijl
  • Peter van Luijk
  • Rob P Coppes
  • Jacobus M Schippers
  • Antonius W T Konings
  • Albert J van der Kogel
چکیده

PURPOSE The dose-response relationship for a relatively short length (4 mm) of rat spinal cord has been shown to be significantly modified by adjacent low-dose fields. In an additional series of experiments, we have now established the dose-volume dependence of this effect. METHODS AND MATERIALS Wistar rats were irradiated on the cervical spinal cord with single doses of unmodulated protons (150 MeV) to obtain sharp lateral penumbras, by use of the shoot-through technique, which employs the plateau of the depth-dose profile rather than the Bragg peak. Three types of inhomogeneous dose distributions were administered: Twenty millimeters of cervical spinal cord were irradiated with variable subthreshold (= bath) doses (4 and 18 Gy). At the center of the 20-mm segment, a short segment of 2 mm or 8 mm (= shower) was irradiated with variable single doses. These inhomogeneous dose distributions are referred to as symmetrical bath-and-shower experiments. An asymmetrical dose distribution was arranged by irradiation of 12 mm (= bath) of spinal cord with a dose of 4 Gy. The caudal 2 mm (= shower) of the 12-mm bath was additionally irradiated with variable single doses. This arrangement of inhomogeneous dose distribution is referred to as asymmetrical bath-and-shower experiment. The endpoint for estimation of the dose-response relationships was paralysis of the fore limbs or hind limbs and confirmation by histology. RESULTS The 2-mm bath-and-shower experiments with a 4-Gy bath dose showed a large shift of the dose-response curves compared with the 2-mm single field, which give lower ED50 values of 61.2 Gy and 68.6 Gy for the symmetrical and asymmetrical arrangement, respectively, compared with an ED50 of 87.8 Gy after irradiation of a 2-mm field only. If the bath dose is increased to 18 Gy, the ED50 value is decreased further to 30.9 Gy. For an 8-mm field, addition of a 4-Gy bath dose did not modify the ED50 obtained for an 8-mm field only (23.2 and 23.1 Gy). CONCLUSIONS The spinal cord tolerance of relatively small volumes (shower) is strongly affected by low-dose irradiation (= bath) of adjacent tissue. The results of all bath-and-shower experiments show the effect of a low bath dose to be highest for a field of 2 mm, less for 4 mm, and absent for 8 mm. Adding a 4-Gy bath to only 1 side of a 2-mm field still showed a large effect. Because glial progenitor cells are known to migrate over at least 2 to 3 mm, this observation indicates that interference with stem cell migration is not the most likely mechanism of a bath effect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chronological response of prostacyclin changes to moderately low doses of radiation in Rat cervical spinal cord

Background: Study of vascular and its secretory profile changes is an important issue in pathogenesis of radiation myelopathy. This paper reports the prostacyclin concentration changes after low-moderate doses of X-irradiation within a short period of time. Materials and Methods: Cervical cords of Wistar rats were irradiated to doses of 0.5, 1, 2, 4 and 6 Gy X-rays. After 24 hours, 2 and 13 ...

متن کامل

An Assessment of Spinal Cord Dose Following Radiotherapy of Nasopharyngeal Cancer by TLD and Rando Phantom

Introduction: Nasopharyngeal carcinoma is one of the most common malignancies in the head and neck region and radiotherapy is its treatment of choice. In spite of the fact that it is widely used, due to the presence of many sensitive organs or tissues in this region, patients may suffer from a wide range of side effects. One such sensitive tissue is the spinal cord. If the absorbed dose to spin...

متن کامل

Unexpected changes of rat cervical spinal cord tolerance caused by inhomogeneous dose distributions.

PURPOSE The effects of dose distribution on dose-effect relationships have been evaluated and, from this, iso-effective doses (ED(50)) established. METHODS AND MATERIALS Wistar rats were irradiated on the cervical spinal cord with single doses of unmodulated protons (150 MeV) to obtain sharp lateral penumbras, using the shoot-through technique, which employs the plateau of the depth-dose prof...

متن کامل

Dose Measurements of Parotid Glands and Spinal Cord in Conventional Treatment of Nasopharyngeal Carcinoma Using RANDO Phantom and Thermoluminescent Dosimeters

Introduction Radiotherapy is regarded as the first treatment of choice for nasopharyngeal carcinoma. Despite the advantages of radiotherapy, patients may suffer from a wide range of side-effects due to the presence of many sensitive normal tissues in these regions. If the absorbed dose exceeds the tolerance level in parotid glands and the spinal cord, myelopathy, Lhermitte's sign and xerostomia...

متن کامل

Techniques for precision irradiation of the lateral half of the rat cervical spinal cord using 150 MeV protons [corrected].

Techniques for high precision irradiation experiments with protons, to investigate the volume dependence of the tolerance dose of the rat cervical spinal cord are described. In the present study, 50% of the lateral cross section of the spinal cord was irradiated. The diameter of the cross section of this part of the rat spinal cord is at maximum 3.5 mm. Therefore, a dedicated procedure was deve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 2006