Echo-enhanced transcranial color-coded duplexsonography to study collateral blood flow in patients with symptomatic obstructions of the internal carotid artery and limited acoustic bone windows.

نویسندگان

  • G Gahn
  • G Hahn
  • S Hallmeyer-Elgner
  • A Kunz
  • T Straube
  • H Bourquain
  • H Reichmann
  • R von Kummer
چکیده

We prospectively evaluated 30 consecutive patients with echo-enhanced transcranial color-coded duplexsonography (TCCD) and correlative transfemoral digital subtraction angiography to assess the diagnostic efficacy of echo-enhanced TCCD for evaluation of collateral pathways through the circle of Willis in patients with limited acoustic bone windows and critical symptomatic carotid disease. Echo-enhanced TCCD detected collateral blood flow through the anterior communicating artery in 16 of 18 patients (sensitivity 89%, 95% CI 65-99%) and was false positive in one out of 12 patients without collateral flow (specificity 92%, 95% CI 59-100%). For the posterior communicating artery, sensitivity was 11/14 (79%, 95% CI 49-95%) and specificity was 15/16 (94%, 95% CI 70-100%). Echo-enhanced TCCD enables to study collateral blood flow through the communicating arteries of the circle of Willis with high sensitivity and specificity in patients with obstructions of the internal carotid artery and limited acoustic bone windows.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benefit of echocontrast-enhanced transcranial color-coded duplex ultrasound in the assessment of intracranial collateral pathways.

BACKGROUND AND PURPOSE Although clinically important, proper assessment of intracranial arterial collateral pathways by transcranial color-coded duplex sonography (TCCD) in patients with internal carotid artery (ICA) high-grade stenosis or occlusion is occasionally made difficult by an insufficient temporal bone window, an unfavorable insonation angle, or low flow velocity or volume. In these c...

متن کامل

Contrast-enhanced transcranial color-coded duplexsonography in stroke patients with limited bone windows.

BACKGROUND AND PURPOSE Thickening of the temporal bone in stroke-age patients may obviate sonographic evaluation of the circle of Willis in 20% to 30% of patients. We assessed the diagnostic efficacy of contrast-enhanced transcranial color-coded duplexsonography (TCCD) for noninvasive evaluation of the circle of Willis in stroke patients with limited bone windows. METHODS Of 171 consecutive p...

متن کامل

Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis.

PURPOSE To determine the sensitivity, specificity, and positive and negative predictive values of transcranial color-coded duplex sonographic (TCCD) evaluation of cross flow through the anterior (ACoA) and posterior (PCoA) communicating arteries in patients with occlusive cerebrovascular disease. METHODS We studied prospectively 132 patients (37 women, 95 men; mean age, 60 years) with stenose...

متن کامل

Noninvasive assessment of the circle of Willis in cerebral ischemia: the potential of CT angiography and contrast-enhanced transcranial color-coded duplexsonography.

Thirty-four patients with acute hemispheric ischemic strokes underwent both CT angiography and contrast-enhanced transcranial color-coded duplexsonography (TCCD) to study the effectiveness of the combined noninvasive techniques for evaluation of the circle of Willis. In 3/34 patients, CT angiography and contrast-enhanced TCCD demonstrated middle cerebral artery (MCA) occlusion, in 5 others MCA ...

متن کامل

Assessment of intracranial collateral flow by using dynamic arterial spin labeling MRA and transcranial color-coded duplex ultrasound.

BACKGROUND AND PURPOSE To evaluate the potential of a new dynamic MRA sequence (DynAngio) based on arterial spin labeling for the assessment of intracranial collateral flow. METHODS Twelve patients with unilateral internal carotid artery obstruction were investigated. Different patterns of collateral flow were compared between DynAngio, transcranial color-coded duplex ultrasound, and time-of-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cerebrovascular diseases

دوره 11 2  شماره 

صفحات  -

تاریخ انتشار 2001