Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

نویسندگان

  • Gonzalo Muñoz
  • César Albarrán-Diego
  • Teresa Ferrer-Blasco
  • Hani F Sakla
  • Santiago García-Lázaro
چکیده

PURPOSE To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). SETTING Private practice surgery center, Valencia, Spain. DESIGN Cohort study. METHODS Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. RESULTS In the multifocal group, the mean binocular corrected distance visual acuity (logMAR) was -0.04 ± 0.07 at 6 m, 0.11 ± 0.10 at 1 m, and 0.06 ± 0.07 at 40 cm. The defocus curve showed little intermediate vision drop off. Photopic contrast sensitivity for distance was similar to the monofocal IOL contrast sensitivity function, while photopic contrast sensitivity for near and mesopic contrast sensitivity for distance with or without glare was reduced at high frequencies. The mean patient satisfaction was 8.09 ± 1.30 (scale 0 to 10); 84.4% of patients were completely independent of spectacles. Moderate halos, glare, and night-vision problems were reported by 6.2%, 12.5%, and 15.6% of patients, respectively. CONCLUSION The new-generation multifocal IOL provided adequate distance, intermediate, and, to a lesser extent, near vision with high rates of spectacle freedom. Halos occurred, and other photic phenomena should be expected in a small percentage of patients. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens Cirurgia de cristalino transparente com lente intraocular multifocal asférica difrativa Teresa Ferrer-Blasco1, sanTiago garcía-lázaro1, césar alBarrán-Diego1, lurDes BelDa-salmerón1, roBerT monTés-micó1

The main goal of a presbyopic patient is to reduce dependence on optical aids and improve both distance and near vision as well as the range of clear vision. Several studies report good safety, predictability, and efficacy outcomes in the implantation with monofocal, toric and multifocal intraocular lenses (IOLs) after refractive lens exchange (RLE). Patients with hybrid spherical IOLs show goo...

متن کامل

Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...

متن کامل

Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison.

AIM To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). METHODS Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular...

متن کامل

Intraocular Lens Multifocality Combined with the Compensation for Corneal Spherical Aberration: A New Concept of Presbyopia-Correcting Intraocular Lens

The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL) Tecnis ZMB00 (Abbott Medical Optics) are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years) underwent phacoemulsification surgery with implantation of this aspheric mu...

متن کامل

Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens.

PURPOSE To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySofReSTOR (SN6AD3 model) intraocular lens (IOL). METHODS Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 2011