Micrometer axial resolution OCT for corneal imaging
نویسندگان
چکیده
An optical coherence tomography (OCT) for high axial resolution corneal imaging is presented. The system uses 375 nm bandwidth (625 to 1000 nm) from a broadband supercontinuum light source. The system was developed in free space to minimize image quality degradation due to dispersion. A custom-designed spectrometer based on a Czerny Turner configuration was implemented to achieve an imaging depth of 1 mm. Experimentally measured axial resolution was 1.1 μm in corneal tissue and had a good agreement with the theoretically calculated resolution from the envelope of the spectral interference fringes. In vivo imaging was carried out and thin corneal layers such as the tear film and the Bowman's layer were quantified in normal, keratoconus, and contact lens wearing eyes, indicating the system's suitability for several ophthalmic applications.
منابع مشابه
In vivo corneal high-speed, ultra high-resolution optical coherence tomography.
OBJECTIVE To introduce new corneal high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT) technology that improves the evaluation of complicated and uncomplicated cataract, corneal, and refractive surgical procedures. DESIGN This case series included a control subject and 9 eyes of 8 patients who had undergone phacoemulsification, Descemet membrane stripping endokeratoplas...
متن کاملHigh resolution in vivo intra-arterial imaging with optical coherence tomography.
BACKGROUND Optical coherence tomography (OCT) is a new method of catheter based micron scale imaging. OCT is analogous to ultrasound, measuring the intensity of backreflected infrared light rather than sound waves. OBJECTIVE To demonstrate the ability of OCT to perform high resolution imaging of arterial tissue in vivo. METHODS OCT imaging of the abdominal aorta of New Zealand white rabbits...
متن کاملSimultaneous SLO/OCT imaging of the human retina with axial eye motion correction.
It has been shown that transversal scanning (or en-face) optical coherence tomography (TS-OCT) represents an imaging modality capable to record high isotropic resolution images of the human retina in vivo. However, axial eye motion still remains a challenging problem of this technique. In this paper we introduce a novel method to compensate for this eye motion. An auxiliary spectral domain part...
متن کاملLens-based wavefront sensorless adaptive optics swept source OCT
Optical coherence tomography (OCT) has revolutionized modern ophthalmology, providing depth resolved images of the retinal layers in a system that is suited to a clinical environment. Although the axial resolution of OCT system, which is a function of the light source bandwidth, is sufficient to resolve retinal features at a micrometer scale, the lateral resolution is dependent on the delivery ...
متن کاملFundamentals of Optical Coherence Tomography: A Critical Review
OCT is a high resolution imaging modality that uses low coherence interferometry (LCI) techniques (in situ and real time) with axial resolution of 1–15μm to perform high resolution imaging of biological tissues [1]. OCT is suitable for real time imaging modality of transparent tissues up to depth limit of ~2 mm by scanning the reference mirror. [2,3]. Initially, LCI was applied in measurement o...
متن کامل