Skin impedance is not a factor in transcutaneous electrical nerve stimulation effectiveness

نویسندگان

  • Carol GT Vance
  • Barbara A Rakel
  • Dana L Dailey
  • Kathleen A Sluka
چکیده

OBJECTIVE Transcutaneous electrical nerve stimulation (TENS) is a nonpharmacological intervention used to manage pain using skin surface electrodes. Optimal electrode placement is unclear. We hypothesized that better analgesia would occur if electrodes were placed over sites with lower skin impedance. Optimal site selection (OSS) and sham site selection (SSS) electrode sites on the forearm were identified using a standard clinical technique. METHODS Experiment 1 measured skin impedance in the forearm at OSS and SSS. Experiment 2 was a crossover design double-blind randomized controlled trial comparing OSS-TENS, SSS-TENS, and placebo TENS (P-TENS) to confirm differences in skin impedance between OSS and SSS, and measure change in pressure pain threshold (PPT) following a 30-minute TENS treatment. Healthy volunteers were recruited (ten for Experiment 1 [five male, five female] and 24 for Experiment 2 [12 male, 12 female]). TENS was applied for 30 minutes at 100 Hz frequency, 100 µs pulse duration, and "strong but nonpainful" amplitude. RESULTS Experiment 1 results demonstrate significantly higher impedance at SSS (17.69±1.24 Ω) compared to OSS (13.53±0.57 Ω) (P=0.007). For Experiment 2, electrode site impedance was significantly higher over SSS, with both the impedance meter (P=0.001) and the TENS unit (P=0.012) compared to OSS. PPT change was significantly greater for both OSS-TENS (P=0.024) and SSS-TENS (P=0.025) when compared to P-TENS. PPT did not differ between the two active TENS treatments (P=0.81). CONCLUSION Skin impedance is lower at sites characterized as optimal using the described technique of electrode site selection. When TENS is applied at adequate intensities, skin impedance is not a factor in attainment of hypoalgesia of the forearm in healthy subjects. Further investigation should include testing in patients presenting with painful conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Action Potential Simulation and Transcutaneous Electrical Nerve Stimulation on Pain and Function of Patients With Chronic Mechanical Shoulder Impairment

Purpose: Rehabilitation and physiotherapy have a major role in reducing the pain and increasing the functional ability in patients with shoulder joint pain. This study aimed to evaluate the effect of Action Potential Simulation (APS) and Transcutaneous Electrical Nerve Stimulation (TENS) in patients with Chronic Mechanical Shoulder Pain (CMSP).  Methods: In this quasi-experimental stu...

متن کامل

Conductive differences in electrodes used with transcutaneous electrical nerve stimulation devices.

The purpose of this study was to document conductive differences among commercially available electrodes used with transcutaneous electrical nerve stimulation (TENS) devices. Impedance within a model system involving a human subject was calculated from oscilloscopic tracings of the pulse waveform for each of 25 different electrode types. Impedance values ranged from 1,000 to 7,800 omega Possibl...

متن کامل

Comparative Use of Electromyography in the Evaluation of Electroacupuncture and Transcutaneous Electrical Neural Stimulation (TENS) Effect on Regeneration of Sciatic Nerve in Dog

Objective-To determine the effect of Electroacupuncture and Transcutaneous Electrical Neural Stimulation on Regeneration of Sciatic Nerve in Dog   Design - Experimental in vivo study. Animals - A total of 15 adult male mixed bred dogs, weighing 26±2.6 Kg/BW with aging of 42±6 months, which were divided into three groups of  5 dogs. Procedures-Under general anesthesia, the right sciatic nerv...

متن کامل

Vagus nerve stimulation in the treatment of nervous system disease: a review article

The vagus nerve (VN), the longest cranial nerve and an essential part of the parasympathetic system, connects the central nervous system to respiratory, cardiovascular, immune, gastrointestinal, and endocrine systems and is involved in the maintenance of homeostasis by controlling these systems. Vagus nerve stimulation (VNS) is related to any method that would stimulate the vagal nerve via elec...

متن کامل

Dynamic Impedance Model of the Skin-Electrode Interface for Transcutaneous Electrical Stimulation

Transcutaneous electrical stimulation can depolarize nerve or muscle cells applying impulses through electrodes attached on the skin. For these applications, the electrode-skin impedance is an important factor which influences effectiveness. Various models describe the interface using constant or current-depending resistive-capacitive equivalent circuit. Here, we develop a dynamic impedance mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015