Multi-residue analysis of pesticides by GC-HRMS
ثبت نشده
چکیده
Dr. Hans Mol is senior scientist at RIKILTWageningen UR Introduction Regulatory authorities throughout the world set and enforce strict limits on the maximum residue levels (MRLs or tolerances) of pesticides permitted on food and feeds. It falls to analytical laboratories to test these products and ensure they meet the relevant standards. The analytical challenge is to look for over 1,500 potential pesticide analytes, at low concentration, in a wide variety of samples of different matrix complexity; it’s a big job. The MRLs tend to be low; In the EU, for example, the default MRL is set at 0.01 mg/kg. Finally, laboratories often need to process large numbers of samples each day. Such high throughput analyses call for a flexible, sensitive, and robust platform. In this paper, we will discuss the use of Thermo Scientific GC Orbitrap system for multi-residue analysis of pesticides. We’ll begin with a brief introduction to the challenge, followed by a description of the operation and then we will highlight the advantages and limitations of the Orbitrap system.
منابع مشابه
A Multi Residue GC-MS Method for Determination of 12 Pesticides in Cucumber
Cucumber is one of the main vegetables in Iranian food basket. A wide range of pesticides are used for crops protection during the cultivation of vegetables such as cucumber due to heavy pest infestation. Analysis of pesticide residues in food and other environmental commodities have become essential requirement for consumers, producers, and food quality control authorities. This study was aime...
متن کاملA Multi Residue GC-MS Method for Determination of 12 Pesticides in Cucumber
Cucumber is one of the main vegetables in Iranian food basket. A wide range of pesticides are used for crops protection during the cultivation of vegetables such as cucumber due to heavy pest infestation. Analysis of pesticide residues in food and other environmental commodities have become essential requirement for consumers, producers, and food quality control authorities. This study was aime...
متن کاملMulti-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS)
Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket.Me...
متن کاملMulti-residue analysis of pesticides by GC-HRMS
Dr. Hans Mol is senior scientist at RIKILTWageningen UR Introduction Regulatory authorities throughout the world set and enforce strict limits on the maximum residue levels (MRLs or tolerances) of pesticides permitted on food and feeds. It falls to analytical laboratories to test these products and ensure they meet the relevant standards. The analytical challenge is to look for over 1,500 poten...
متن کاملExposure Assessment for Some Pesticides through Rice Consumption in Iran Using a Multiresidue Analysis by GC-MS
In communities which consume rice as main food, importance of risk assessment forcontaminants is always taken into consideration by health authorities. The present study isan attempt for monitoring of 56 pesticides from different chemical groups in rice samplescollected from local markets in Tehran and estimation of daily intake of interested pesticidesthrough this monitoring. A valid method ba...
متن کامل