Wave Propagation Regime to Point to Faulty Feeder in a Mixed Cable-and-Lines Distribution Systems with an SLG Fault
نویسندگان
چکیده
-In radial distribution network with no discontinuities in feeders’ impedances the shape of traveling wave induced by an SLG fault inception will be modeled by multiple refractions and reflections from busbar, fault and loads. The initial propagation zone presents a rigorous polarity disposition of residual currents, with sound residuals having the same polarity. We can determine the minimal sampling frequency necessary to get in that zone the current data indicating faulty feeder. The initial polarity length does not depend on the fault position, its resistance value or on the soil resistivity, and if scrutinized on all feeders it can point out from busbar to fault in systems with laterals. The propagating waves can thus be involved in directional procedures in lines or in cables. Under certain conditions the directional function can be assumed also in mixed networks, with feeders partly in cables and partly in lines.
منابع مشابه
A Mixed Integer Programming Approach to Optimal Feeder Routing for Tree-Based Distribution System: A Case Study
A genetic algorithm is proposed to optimize a tree-structured power distribution network considering optimal cable sizing. For minimizing the total cost of the network, a mixed-integer programming model is presented determining the optimal sizes of cables with minimized location-allocation cost. For designing the distribution lines in a power network, the primary factors must be considered as m...
متن کاملSymmetric Components for Transient Regime Application in MV Systems
In order to apply advantageously the symmetrical components theory to SLG fault transients in distribution systems we take profit of similitude of transient components in faulty phase current and in zero sequence current on faulty feeder. Then we are able to take into account the load current contribution within voltage drop account of zero sequence equivalent circuit. The result is an Extended...
متن کاملمکان یابی خطا در شبکه های توزیع فشار متوسط دو مداره به روش امپدانسی
Power distribution feeders contains many laterals, sub-laterals, different number of circuit line, load taps, balanced and unbalanced load, different type of lines (cable or overhead), different cross-sections and numerous distribution transformers with different capacities. Moreover, the voltage and current are measured only at the beginning of the feeder. Thus, fault location is very complex....
متن کاملTransient Regime to Support Steady State Directional Function in Presence of Strong Capacitive Currents in Compensated MV Systems
An SLG fault detection task can be out of reach of steady state methods, based on detection of active component in faulty currents. Efficiency of these methods may not be assured when strong capacitive currents on faulty feeder squeeze the phase shift between the faulty and the sound zero sequence currents below actual acquisition limits. Then the way to assure the directional decision is to ex...
متن کاملالگوریتم جامعی برای مکان یابی خطا در خطوط انتقال دو مداره و چند پایانه ای (بیش از سه پایانه) مبتنی بر داده های PMU
A new PMU-based fault detection/location algorithm for multi-terminal transmission lines is proposed in this paper, which works on the basis of synchronized voltage and current phasors received from PMUs installed in various terminals. The Clark transform (for transposed transmission lines), Eigen-values and eigenvectors theory (for un-transposed ones) are used to decouple 3-phase differential ...
متن کامل