A rapid ELISA for the diagnosis of intravascular catheter related sepsis caused by coagulase negative staphylococci.

نویسندگان

  • T Worthington
  • P A Lambert
  • A Traube
  • T S J Elliott
چکیده

AIM To develop and evaluate a rapid enzyme linked immunosorbent assay (ELISA) for the diagnosis of intravascular catheter related sepsis caused by coagulase negative staphylococci. METHODS Forty patients with a clinical and microbiological diagnosis of intravascular catheter related sepsis and positive blood cultures, caused by coagulase negative staphylococci, and 40 control patients requiring a central venous catheter as part of their clinical management were recruited into the study. Serum IgG responses to a previously undetected exocellular antigen produced by coagulase negative staphylococci, termed lipid S, were determined in the patient groups by a rapid ELISA. RESULTS There was a significant difference (p = < 0.0001) in serum IgG to lipid S between patients with catheter related sepsis and controls. The mean antibody titre in patients with sepsis caused by coagulase negative staphylococci was 10 429 (range, no detectable serum IgG antibody to 99 939), whereas serum IgG was not detected in the control group of patients. CONCLUSIONS The rapid ELISA offers a simple, economical, and rapid diagnostic test for suspected intravascular catheter related sepsis caused by coagulase negative staphylococci, which can be difficult to diagnose clinically. This may facilitate treatment with appropriate antimicrobials and may help prevent the unnecessary removal of intravascular catheters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of continuous monitoring blood culture systems in the diagnosis of catheter related sepsis.

AIM To assess whether the information provided by automated continuous monitoring blood culture systems could aid in the diagnosis of catheter related sepsis. METHODS Serial dilutions of a strain of coagulase negative staphylococcus were inoculated into the BacT/Alert blood culture system. Blood culture results for seven patients with possible catheter related sepsis from coagulase negative s...

متن کامل

Adherence of coagulase-negative staphylococci to plastic tissue culture plates: a quantitative model for the adherence of staphylococci to medical devices.

The adherence of coagulase-negative staphylococci to smooth surfaces was assayed by measuring the optical densities of stained bacterial films adherent to the floors of plastic tissue culture plates. The optical densities correlated with the weight of the adherent bacterial film (r = 0.906; P less than 0.01). The measurements also agreed with visual assessments of bacterial adherence to culture...

متن کامل

Biofilms, Coagulase Negative Staphylococci and the Saga of Catheter Related Bloodstream Infections

Catheter related bloodstream infections are a major problem in most tertiary care hospitals. Among the various organisms associated with nosocomial infections, coagulase negative staphylococci are responsible for majority of the catheter related infections. They are usually resistant to standard antibiotics necessitating prolonged hospital stay and amplifying the cost of treatment manifold whic...

متن کامل

Inflammation at the insertion site is not predictive of catheter-related bloodstream infection with short-term, noncuffed central venous catheters.

BACKGROUND Noncuffed, percutaneously inserted central venous catheters (CVCs) are widely used and cause at least 250,000 bloodstream infections (BSIs) in U.S. hospitals each year. We report a prospective study to determine whether inflammation at the insertion site is predictive of CVC-related BSI. METHODS Percutaneously inserted, noncuffed CVCs inserted into the subclavian, internal jugular,...

متن کامل

Colonization of bacteria on polyvinyl chloride and Teflon intravascular catheters in hospitalized patients.

During an 8-month period all intravascular catheters were removed by sterile technique upon completion of use and submitted to the hospital microbiology laboratory. All catheters were routinely cultured by the semiquantitative culture technique, with greater than or equal to 15 colonies being defined as a positive result. Of the 687 Teflon catheters cultured, 6.9% were positive by culture, comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 55 1  شماره 

صفحات  -

تاریخ انتشار 2002