Sedation assessment in a mobile intensive care unit: a prospective pilot-study on the relation of clinical sedation scales and the bispectral index

نویسندگان

  • Johannes Prottengeier
  • Andreas Moritz
  • Sebastian Heinrich
  • Christine Gall
  • Joachim Schmidt
چکیده

INTRODUCTION The critically-ill undergoing inter-hospital transfers commonly receive sedatives in continuation of their therapeutic regime or to facilitate a safe transfer shielded from external stressors. While sedation assessment is well established in critical care in general, there is only little data available relating to the special conditions during patient transport and their effect on patient sedation levels. The aim of this prospective study was to investigate the feasibility and relationship of clinical sedation assessment (Richmond Agitation-Sedation Scale (RASS)) and objective physiological monitoring (bispectral index (BIS)) during patient transfers in our Mobile-ICU. METHODS The levels of sedation of 30 pharmacologically sedated patients were evaluated at 12 to 17 distinct measurement points spread strategically over the course of a transfer by use of the RASS and BIS. To investigate the relation between the RASS and the BIS, Spearman's squared rank correlation coefficient (ρ(2)) and the Kendall's rank correlation coefficient (τ) were calculated. The diagnostic value of the BIS with respect to the RASS was investigated by its sensitivity and positive predictive value for possible patient awakening. Therefore, measurements were dichotomized considering a clinically sensible threshold of 80 for BIS-values and classifying RASS values being nonnegative. RESULTS Spearman's rank correlation resulted to ρ(2) = 0.431 (confidence interval (CI) = 0.341 to 0.513). The Kendall's correlation coefficient was calculated as τ = 0.522 (CI = 0.459 to 0.576). Awakening of patients (RASS ≥ 0) was detected by a BIS value of 80 and above with a sensitivity of 0.97 (CI = 0.89 to 1.00) and a positive predictive value of 0.59 (CI = 0.45 to 0.71). CONCLUSIONS Our study demonstrates that the BIS-Monitor can be used for the assessment of sedation levels in the intricate environment of a Mobile-ICU, especially when well-established clinical scores as the RASS are impracticable. The use of BIS is highly sensitive in the detection of unwanted awakening of patients during transfers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assesment of correlation between bispectral index and four common sedation scales used in mechanically ventilated patients in ICU.

PURPOSE The aim of this study was to compare the correlation between bispectral index (BIS) monitor and four commonly used subjective clinical scales (Ramsay Sedation Scale (RSS), Richmond Agitation Sedation Scale (RASS), Sedation Agitation Scale, Adaptation to Intensive Care Environment scale) in mechanically ventilated patients in intensive care unit (ICU). In addition, comparison of responsi...

متن کامل

Bispectral index values, sedation-agitation scores, and plasma Lorazepam concentrations in critically ill surgical patients.

BACKGROUND Publications on the use of the bispectral index for sedation monitoring in the intensive care unit are increasing. However, few studies have involved correlation of bispectral index with serum drug concentrations. OBJECTIVES To assess the degree of correlation between bispectral index values, scores on the Sedation-Agitation Scale, and steady-state serum concentrations of lorazepam...

متن کامل

Bispectral index versus COMFORT score to determine the level of sedation in paediatric intensive care unit patients: a prospective study

INTRODUCTION Most clinicians give sedatives and analgesics according to their professional experience and the patient's estimated need for sedation. However, this approach is prone to error. Inadequate monitoring of sedation and analgesia may contribute to adverse outcomes and complications. With this in mind, data obtained continuously using nonstimulating methods such as bispectral index (BIS...

متن کامل

Correction: Bispectral index versus COMFORT score to determine the level of sedation in paediatric intensive care unit patients: a prospective study

References 1. Triltsch AE, Nestmann G, Orawa H, Moshirzadeh M, Sander M, Große J, Genähr A, Konertz W, Spies CD: Bispectral index versus COMFORT score to determine the level of sedation in paediatric intensive care unit patients: a prospective study. Crit Care 2005, 9:R9-R17 Correction Correction: Bispectral index versus COMFORT score to determine the level of sedation in paediatric intensive c...

متن کامل

Performance of the A-line Autoregressive Index (AAI) and of the Bispectral Index (BIS) at assessing depth of short-term sedation following cardiac surgery.

This study evaluated the correlation and agreement between the Bispectral Index (BIS) or A-line Autoregressive Index (AAI) and a clinical scoring system, the Ramsay Sedation Scale (RSS), in 40 patients after elective cardiac surgery and admission to the intensive care unit. All patients received sedation with propofol according to the study protocol. BIS, AAI and RSS were documented at two diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2014