Enhanced weak-signal sensitivity in two-photon microscopy by adaptive illumination.
نویسندگان
چکیده
We describe a technique to enhance both the weak-signal relative sensitivity and the dynamic range of a laser scanning optical microscope. The technique is based on maintaining a fixed detection power by fast feedback control of the illumination power, thereby transferring high measurement resolution to weak signals while virtually eliminating the possibility of image saturation. We analyze and demonstrate the benefits of adaptive illumination in two-photon fluorescence microscopy.
منابع مشابه
Pupil-segmentation-based adaptive optical microscopy with full-pupil illumination.
Optical aberrations deteriorate the performance of microscopes. Adaptive optics can be used to improve imaging performance via wavefront shaping. Here, we demonstrate a pupil-segmentation based adaptive optical approach with full-pupil illumination. When implemented in a two-photon fluorescence microscope, it recovers diffraction-limited performance and improves imaging signal and resolution.
متن کاملAdaptive optics two photon scanning laser fluorescence microscopy
Two-photon fluorescence microscopy provides a powerful tool for deep tissue imaging. However, optical aberrations from illumination beam path limit imaging depth and resolution. Adaptive Optics (AO) is found to be useful to compensate for optical aberrations and improve image resolution and contrast from two-photon excitation. We have developed an AO system relying on a MEMS Deformable Mirror (...
متن کاملA fusion-based enhancing method for weakly illuminated images
We propose a straightforward and efficient fusion-based method for enhancing weakly illumination images that uses several mature image processing techniques. First, we employ an illumination estimating algorithm based on morphological closing to decompose an observed image into a reflectance image and an illumination image. We then derive two inputs that represent luminance-improved and contras...
متن کاملA flexible, computer-controlled video microscope capable of quantitative spatial, temporal, and spectral measurements.
A video microscope system has been constructed and tested that incorporates computer-controlled video cameras for high-resolution and low-light microscopy. The low-light camera system involves a dual microchannel plate-image intensifier capable of photon gain as high as 500 000 and a gated silicone-intensified target vidicon to achieve usable photon sensitivity with a noise equivalent signal of...
متن کاملImproving the velocity tracking of cruise control system by using adaptive methods
Accurate and correct performance of controller in cruise control systems is important. Hence, in such systems, controller should optimize itself against noise and probable changes in system dynamic. As a matter of fact, in this article three approaches have been conducted to-ward this purpose: MIT, direct estimation and indirect estimation. These approaches are used as controllers to track refe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 32 19 شماره
صفحات -
تاریخ انتشار 2007