Clinical evaluation of scanning laser polarimetry: II. Polar profile shape analysis.

نویسندگان

  • A Waldock
  • M J Potts
  • J M Sparrow
  • W S Karwatowski
چکیده

AIMS To devise a method to describe and quantify the shape of polar profiles obtained with the scanning laser polarimeter and to compare this measurement with other polar profile measurements in a series of normal subjects and glaucoma patients. METHODS Scanning laser polarimetry was performed on 54 normal subjects and 74 glaucoma patients. The retardation values obtained from one randomly chosen eye of each subject were analysed using our own methods, including the use of an algorithm to remove blood vessels from the polar profiles, an algorithm to standardise the glaucoma profiles to a normal database, and a further algorithm to evaluate the profile shape. The measurements of profile shape were compared with measurements of the absolute and standardised retinal nerve fibre layer thickness obtained with the scanning laser polarimeter. RESULTS There was no significant difference between the mean retardation values for the normal and glaucomatous subjects in either hemiretina. However, standardisation of the glaucoma retardation values to a normal database produced significant differences at p < 1 x 10-8 in the mean retardation values for these two groups in both hemiretinas. Profile shape measurement analysis produced similar significant differences between the mean retardation values for the normal and glaucomatous subjects in both hemiretinas, although the degree of separation was greater following standardisation of the retardation values. CONCLUSION The use of an algorithm to standardise an individual's retardation values in conjunction with a blood vessel removal algorithm enables an improvement in the ability of the scanning laser polarimeter to discriminate between normal and glaucomatous patients. The polar profile shape algorithm is independent of standardisation and significantly improves the discrimination between normal and glaucomatous patients, as well as providing additional information regarding the retinal nerve fibre layer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of scanning laser polarimetry: I. Intraoperator reproducibility and design of a blood vessel removal algorithm.

AIMS To evaluate the reproducibility of the retardation values (change in polarisation) obtained with the scanning-laser polarimeter in a series of normal subjects and glaucoma patients. To improve the analysis of the raw data by devising and evaluating a blood vessel removal algorithm. METHODS Scanning laser polarimetry was performed on 10 normal subjects and 10 glaucoma patients. A series o...

متن کامل

Scanning laser polarimetry of the retinal nerve fibre layer in primary open angle and capsular glaucoma.

AIMS To evaluate the clinical value of scanning laser polarimetry with the nerve fibre analyser type II in primary open angle glaucoma (POAG) and capsular glaucoma. METHODS Scanning laser polarimetry was performed on one eye of 30 patients suffering from POAG, 25 patients suffering from capsular glaucoma, and on 35 healthy control subjects. The retinal nerve fibre layer (RNFL) thickness value...

متن کامل

Influence of cycloversions induced by head tilt on scanning laser polarimetry parameters.

OBJECTIVE To study the influence of cycloversions induced by head tilt on parameters of scanning laser polarimetry. METHODS Five left and five right eyes of 9 normal subjects were measured in seven different head tilt positions by one examiner using a scanning laser polarimeter (Nerve Fiber Analyzer, NFA II, LDT Inc., San Diego, Calif., USA). Images were acquired for the following head tilt p...

متن کامل

Accuracy of scanning laser polarimetry in the diagnosis of glaucoma.

OBJECTIVE To determine the diagnostic accuracy of scanning laser polarimetry. SUBJECTS AND METHODS A total of 95 healthy subjects and 102 patients with glaucoma met all inclusion criteria. Data collected on each participant included an automated visual field examination, stereoview optic nerve head photographs, intraocular pressure measurement, and a screening and full scanning laser polarime...

متن کامل

Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma.

PURPOSE To apply Fourier analysis to the retinal nerve fiber layer (RNFL) thickness measurements obtained with scanning laser polarimetry (SLP), by using variable corneal compensation, and to evaluate the ability of this method to discriminate glaucomatous from normal eyes. METHODS The study included one eye each of 55 patients with glaucoma and 52 healthy subjects. RNFL thickness measurement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 1998