Characterizing tissue stiffness at the tip of a rigid needle using an opto-mechanical force sensor
نویسندگان
چکیده
We present a novel device that allows the user to measure the Young Modulus of a material at the opening of a 5 mm diameter needle. The device relies on a miniaturized cantilever spring mounted at the end of the needle and interrogated via Fabry-Pérot optical fiber interferometry. The probe is repetitively brought in and out of contact with the sample at the end of the needle by means of a steel cable that is controlled via a piezoelectric actuator located at the proximal end. We demonstrate the ability of our device to detect and quantify layers of varying stiffness during needle insertion in a gelatin phantom and to successfully locate tissue boundaries in bovine liver tissue embedded in gelatin.
منابع مشابه
Fiber-Optic Fabry-Pérot Interferometers for Axial Force Sensing on the Tip of a Needle
A range of complex percutaneous procedures, such as biopsy or regional anesthesia, rely heavily on accurate needle insertion. Small variations in the mechanical properties of the pierced tissue can however cause deviations from the projected needle path and can thus result in inaccurate placement of the needle. Navigation of a rigid needle towards the target tissue is traditionally based on the...
متن کاملDesign and Modeling of a New Type of Tactile Sensor Based on the Deformation of an Elastic Membrane
This paper presents the design and modeling of a flexible tactile sensor, capable of detecting the 2D surface texture image, contact-force estimation and stiffness of the sensed object. The sensor is made of polymer materials. It consists of a cylindrical chamber for pneumatic actuation and a membrane with a mesa structure. The inner radius of the cylindrical chamber is 2cm and its outer radius...
متن کاملStudy of the flexural sensitivity and resonant frequency of an inclined AFM cantilever with sidewall probe
The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...
متن کاملStudy of the flexural sensitivity and resonant frequency of an inclined AFM cantilever with sidewall probe
The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...
متن کاملMaster-Thesis Development of a Surgical Assistant System for Needle Adjustment in Prostate Brachytherapy
Title of the Master-Thesis Development of a Surgical Assistant System for Needle Adjustment in Prostate Brachytherapy Author: 1. Examiner: 2. Examiner: Semester: Thomas Lehmann Prof. Dr.-Ing. Bernhard Vondenbusch, Hochschule Furtwangen University Mahdi Tavakoli, PhD, University of Alberta BME 3 Abstract: The prototype of a robotic surgical assistant system was developed for prostate brachythera...
متن کامل