Identifying the provenance of Leach's storm petrels in the North Atlantic using polychlorinated biphenyl signatures derived from comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry.
نویسندگان
چکیده
PCB signatures can be used for source identification, exposure studies, age dating and bio-monitoring. This study uses comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GCxGC-ToFMS) to produce a PCB signature comprised of over 80 PCBs for individual Leach's storm petrels (Oceanodroma leucorhoa). The Leach's storm petrel is a relatively small, elusive, understudied pelagic bird, which only returns to remote islands under darkness during the breeding season. Samples were obtained from 25 Leach's storm petrels found dead in Canada and the UK following storm events in 2006 and 2009. Tissue samples were extracted and analysed by GCxGC-ToFMS and results showed that 83 PCB congeners were present in >60% of samples. An assessment of the PCB signature in four different tissue types showed that it did not vary greatly in samples obtained from the gut, heart, liver and stomach. Multivariate statistical analysis identified a distinctive PCB signature in birds from Canada and Europe which was used to identify the regional provenance and transatlantic movement of individual birds. The findings showcase the ability of GCxGC-ToFMS to provide the high quality congener specific analysis that is necessary for PCB fingerprinting, as well as highlighting the potential of PCB signatures for use in ecological studies of movement, foraging and behaviour.
منابع مشابه
Improved separation of the 209 polychlorinated biphenyl congeners using comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry.
The separation of the 209 polychlorinated biphenyl (PCB) congeners has been studied using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC x GC-TOFMS). Four column combinations based on thermally stable phases, DB-1/HT-8, DB-XLB/HT-8, DB-XLB/BPX-50, and HT-8/BPX-50, have been investigated. The HT-8/BPX-50 set produced the best separation. The dist...
متن کاملCan polychlorinated biphenyl (PCB) signatures and enantiomer fractions be used for source identification and to age date occupational exposure?
Detailed polychlorinated biphenyl (PCB) signatures and chiral Enantiomer Fractions (EFs) of CB-95, CB-136 and CB-149 were measured for 30 workers at a transformer dismantling plant. This was undertaken to identify sources of exposure and investigate changes to the PCB signature and EFs over different exposure periods. Approximately 1.5 g of serum was extracted and PCB signatures were created th...
متن کاملComprehensive two-dimensional gas chromatography time of flight mass spectrometry (GC×GC-TOFMS) for environmental forensic investigations in developing countries.
The disposal and dumping of toxic waste is a matter of growing concern in developing countries, including South Africa. Frequently these countries do not possess access to gas chromatography-high resolution mass spectrometry (GC-HRMS) for the determination of persistent organic pollutants (POPs). This publication describes an alternative approach to the investigation of toxic waste using compre...
متن کاملEstablishing an alternative method for the quantitative analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans by comprehensive two dimensional gas chromatography-time-of-flight mass spectrometry for developing countries.
Comprehensive Gas Chromatography-Time-of-Flight Mass Spectrometry (GC×GC-TOFMS) methodology has been refined for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in samples with different matrices. This is specifically for application in developing countries where access to gas chromatography-high resolution mass spectrometry (GC-HRMS) and high...
متن کاملPolychlorinated biphenyls (PCBs) analysis using a miniaturized high-resolution time-of-flight mass spectrometer "MULTUM-S II".
In this study, we conducted polychlorinated biphenyls (PCBs) analysis using fast gas chromatography (GC)/high-resolution mass spectrometry (HRMS). Mass spectrometry (MS) was performed with a miniature multi-turn time-of-flight (TOF) analyzer called "MULTUM-S II". MULTUM-S II is truly a portable high resolution mass spectrometer. The mass spectrometer's high resolution capability is due to its t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemosphere
دوره 114 شماره
صفحات -
تاریخ انتشار 2014