Closed-loop Control of Egr Using Ion Currents

نویسنده

  • S. Byttner
چکیده

Two virtual sensors are proposed that use the spark-plug based ion current sensor for combustion engine control. The first sensor estimates combustion variability for the purpose of controlling exhaust gas recirculation (EGR) and the second sensor estimates the pressure peak position for control of ignition timing. Use of EGR in engines is important because the technique can reduce fuel consumption and NOx emissions, but recirculating too much can have the adverse effect with e.g. increased fuel consumption and poor driveability of the vehicle. Since EGR also affects the phasing of the combustion (because of the diluted gas mixture with slower combustion) it is also necessary to control ignition timing otherwise efficiency will be lost. The combustion variability sensor is demonstrated in a closed-loop control experiment of EGR on the highway and the pressure peak sensor is shown to handle both normal and an EGR condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Correlations Between COV of Ion Integral and COV of IMEP in a Port-Injected Natural-Gas Engine

Correlations between the coefficient of variations (COV) of ion current integrals and COV of indicated mean effective pressure (IMEP) are investigated. The investigations are made to see if there is a possibility to use ion sense technique for closed loop combustion control to maximize Exhaust Gas Recirculation (EGR) level with remaining combustion stability. The engine studied in this thesis i...

متن کامل

Control of Flexible Link Robot using a Closed Loop Input-Shaping Approach

This paper is has addressed the Single Flexible Link Robot. The dynamical model is derived using Euler-Lagrange equation and then a proper controller is designed to suppress a  vibration based-on Input-Shaping (IS) method. But, IS control method is an open loop strategy. Due to the weakness of open loop control systems, a closed loop IS control system is proposed. The achieved closed loop c...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

A Closed Loop Control of Quadratic Boost Converter Using PID Controller

This paper presents an implementation of open loop and closed loop control of Quadratic boost converter using PID controller.  Quadratic boost converter consists of boost converter and fly back converter driven by a single switch. Quadratic boost converter QBC is designed especially for regulating the DC interface between various micro sources and dc-ac inverter to electricity grid. Quadratic b...

متن کامل

Robust Adaptive Fuzzy Sliding Mode Control of Permanent Magnet Stepper Motor with Unknown Parameters and Load Torque

In this paper, robust adaptive fuzzy sliding mode control is designed to control the Permanent Magnet (PM) stepper motor in the presence of model uncertainties and disturbances. In doing so, the nonlinear model is converted to canonical form, then, for designing the controller, the robust sliding mode control is designed to decrease the effects of uncertainties and disturbances. A class of fuzz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007