B1 field homogeneity and SAR calculations for the birdcage coil.
نویسندگان
چکیده
The finite-difference time-domain (FDTD) method is used to model a birdcage resonator. All the coil components, including the wires, lumped capacitors and the source, are geometrically modelled together. As such, the coupling effects within the birdcage, including the interactions of coil, source and human head, are accurately computed. A study of the transverse magnetic (B1) field homogeneity and the specific absorption rate (SAR) is presented on an anatomically detailed human head model at 64 and 200 MHz representing 1.5 and 4.7 T MRI systems respectively. Unlike that at 64 MHz, the B1 field distribution is found to be inhomogeneous at 200 MHz. Also, high local SAR values are observed in the tissue near the source due to the coupling between the source and the head at 200 MHz.
منابع مشابه
Numerical Comparison Between TEM Head Coil and Birdcage Head Coil at 7T
G. D. DeMeester, Z. Zhai, M. A. Morich, C. Leussler, C. Findeklee Philips Medical Systems, Cleveland, Ohio, United States, Philips Research Laboratories, Hamburg, Hamburg, Germany Introduction A TEM T/R head coil and a shielded birdcage T/R head coil operated at 298MHz/7T were both modeled using the Finite Difference Time Domain (FDTD) method. The two coils have approximately the same physical ...
متن کاملSAR and B1 Field in a Human Head Model for Birdcage, TEM and Microstrip Coils at 7T
Introduction: The advantage of high field MRI is high SNR which can increase image resolution or decrease acquisition time. However, there are some challenges, such as the RF wavelength effect and the power deposition in tissues. A comparison of three different volume coils loaded with the same spherical homogeneous phantom has been reported [1]. In order to mimic the B1 field distribution and ...
متن کاملHow Much Does Coil Geometry Matter in High-Field Brain Imaging? A Numerical Study with High-Fidelity Coil Modeling
Introduction: Transmit coil design at high-field is challenging due to the increasing B1 in-homogeneity and SAR. Both designs with independently controlled elements and non-conventional birdcage-like coils have been proposed [1][2]. The latter has the advantage of simplicity and the ease of manufacturing. However, the effects of applying different volumetric coil patterns have not been careful ...
متن کاملA Method for Accurate Calculation of B1 Fields in Three Dimensions. Effects of Shield Geometry on Field Strength and Homogeneity in the Birdcage Coil
A method for calculating B1 field strength and homogeneity In order to construct an optimal RF system, it is important as functions of radiofrequency shield geometry is presented. The to consider how shield geometry will affect the performance method requires use of three-dimensional finite-element analysis, of the RF system. It is possible to measure B1 field strength birdcage-coil theory, and...
متن کاملDesign of Crisscrossed Double-Layer Birdcage Coil for Improving B1 + Field Homogeneity for Small-Animal Magnetic Resonance Imaging at 300 MHz
We design a crisscrossed double-layer birdcage (DLBC) coil by modifying the coil geometry of a standard single-layer BC (SLBC) coil to enhance the homogeneity of transmitting magnetic flux density (B1 ) along the main magnetic field (B0)-direction for small-animal magnetic resonance imaging (MRI) at 300 MHz. The performance assessment of the crisscrossed DLBC coil is conducted by computational ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2001