BACKGROUND Public health research on sedentary behavior (SB) in youth has heavily relied on accelerometers. However, it has been limited by the lack of consensus on the most accurate accelerometer cut-points as well as by unknown effects caused by accelerometer position (wrist vs. hip) and output (single axis vs. multiple axes). The present study systematically evaluates classification accuracy of different Actigraph cut-points for classifying SB using hip and wrist-worn monitors and establishes new cut-points to enable use of the 3-dimensional vector magnitude data (for both hip and wrist placement). METHODS A total of 125 children ages 7-13 yrs performed 12 randomly selected activities (from a set of 24 different activities) for 5 min each while wearing tri-axial Actigraph accelerometers on both the hip and wrist. The accelerometer data were categorized as either sedentary or non-sedentary minutes using six previously studied cut-points: 100 counts-per-minute (CPM), 200 CPM, 300 CPM, 500 CPM, 800 CPM and 1100 CPM. Classification accuracy was evaluated with Cohen's Kappa (κ) and new cut-points were identified from Receiver Operating Characteristic (ROC). RESULTS Of the six cut-points, the 100 CPM value yielded the highest classification accuracy (κ = 0.81) for hip placement. For wrist placement, all of the cut-points produced low classification accuracy (ranges of κ from 0.44 to 0.67). Optimal sedentary cut-points derived from ROC were 554.3 CPM (ROC-AUC of 0.99) for vector magnitude for hip, 1756 CPM (ROC-AUC of 0.94) for vertical axis for wrist, and 3958.3 CPM (ROC-AUC of 0.93) for vector magnitude for wrist placement. CONCLUSIONS The 100 CPM was supported for use with vertical axis for hip placement, but not for wrist placement. The ROC-derived cut-points can be used to classify youth SB with the wrist and with vector magnitude data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing different accelerometer cut-points for sedentary time in children.

Actigraph accelerometers are hypothesized to be valid measurements for assessing children's sedentary time. However, there is considerable variation in accelerometer cut-points used. Therefore, we compared the most common accelerometer sedentary cut-points of children performing sedentary behaviors. Actigraph Actitrainer uniaxial accelerometers were used to measure children's activity intensity...

متن کامل

Calibration and Cross-Validation of the ActiGraph wGT3X+ Accelerometer for the Estimation of Physical Activity Intensity in Children with Intellectual Disabilities

BACKGROUND Valid objective measurement is integral to increasing our understanding of physical activity and sedentary behaviours. However, no population-specific cut points have been calibrated for children with intellectual disabilities. Therefore, this study aimed to calibrate and cross-validate the first population-specific accelerometer intensity cut points for children with intellectual di...

متن کامل

Agreement between activPAL and ActiGraph for assessing children's sedentary time

BACKGROUND Accelerometers have been used to determine the amount of time that children spend sedentary. However, as time spent sitting may be detrimental to health, research is needed to examine whether accelerometer sedentary cut-points reflect the amount of time children spend sitting. The aim of this study was to: a) examine agreement between ActiGraph (AG) cut-points for sedentary time and ...

متن کامل

A Calibration Protocol for Population-Specific Accelerometer Cut-Points in Children

PURPOSE To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity. METHODS Twenty-eight children (46% boys) aged 10-11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 acti...

متن کامل

Objective Measurement of Physical Activity and Sedentary Behavior Among US Adults Aged 60 Years or Older

INTRODUCTION Estimates of objectively measured physical activity among older adults differ depending on the cut points used to define intensity. Our objective was to assess 1) moderate to vigorous physical activity (MVPA), exploring differences in prevalence depending on the cut point used, and 2) sedentary behavior, among US adults aged 60 years or older. METHODS We used the most recently av...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014