Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway.
نویسندگان
چکیده
BACKGROUND The Bonfils intubation fibrescope (BIF), a rigid, straight and reusable fibreoptic device, is being used increasingly to facilitate endotracheal intubation after direct laryngoscopy has failed. We tested the hypothesis that, with the BIF compared to direct laryngoscopy, the rate of failed endotracheal intubation could be reduced in patients with a difficult airway, simulated by means of a rigid cervical immobilization collar. METHODS Seventy-six adults undergoing elective gynecological surgery under general anesthesia were randomly assigned to have endotracheal intubation, facilitated with either a standard size 3 Macintosh laryngoscope blade, or the BIF. A rigid cervical immobilization collar was used to simulate a difficult airway, by reducing mouth opening and limiting neck extension. If endotracheal intubation could not be achieved within two attempts, the cervical collar was removed, and direct laryngoscopy was performed thereafter, using a Macintosh blade in all subjects. The success rate of endotracheal tube placement was the primary outcome variable. RESULTS Patient characteristics were similar in the two groups. After neck immobilization, the inter-incisor distance was reduced to 2.6 +/- 0.7 cm (Macintosh) and 2.6 +/- 0.8 cm (BIF). Tube placement was successful in 15/38 (39.5%) patients with a Macintosh blade, and in 31/38 patients with the BIF (81.6%; P = 0.0003). Time required for tube placement was 53 +/- 22 sec (Macintosh) and 64 +/- 24 sec (BIF; P = 0.15). CONCLUSION The Bonfils intubation fibrescope is a more effective intubating device for patients with immobilized cervical spine and significantly limited inter-incisor distance, when compared to direct laryngoscopy.
منابع مشابه
Comparison of success of tracheal intubation using Macintosh laryngoscope-assisted Bonfils fiberscope and Truview video laryngoscope in simulated difficult airway
BACKGROUND AND AIMS Restriction of head and neck movements prevents the alignment of the oral, pharyngeal, and laryngeal axes and increases the incidence of difficult tracheal intubation in patients with cervical spine fractures. Video laryngoscopes have gained an important role in the management of difficult intubation, especially in situations with limited head and neck movements. This study ...
متن کاملRigid fibrescope Bonfils: use in simulated difficult airway by novices
BACKGROUND The Bonfils intubation fibrescope is a promising alternative device for securing the airway. We examined the success rate of intubation and the ease of use in standardized simulated difficult airway scenarios by physicians. We compared the Bonfils to a classical laryngoscope with Macintosh blade. METHODS 30 physicians untrained in the use of rigid fibrescopes but experienced in air...
متن کاملNasotracheal intubation: look before you leap.
Nasotracheal intubation is frequently used for airway management during maxillofacial surgery. Complications such as haemorrhage occur more frequently with this route of intubation than with the orotracheal route. This case report describes a male patient aged 51 yr who developed severe epistaxis after the tube had passed the nares. As an additional complication laryngoscopy and endotracheal in...
متن کاملThe i-gel Supraglottic Airway as a Conduit for Fibreoptic Tracheal Intubation - A Randomized Comparison with the Single-use Intubating Laryngeal Mask Airway and CTrach Laryngeal Mask in Patients with Predicted Difficult Laryngoscopy.
Fibreoptic intubation through a supraglottic airway is an alternative plan for airway management in difficult or failed laryngoscopy. The aim of this study was to compare three supraglottic airways as conduits in patients with at least one predictor for difficult laryngoscopy. The i-gel was compared with the single-use intubating laryngeal mask airway (sILMA) and CTrach laryngeal mask in 120 ad...
متن کاملReduced hemodynamic responses to tracheal intubation by the Bonfils retromolar fiberscope: a randomized controlled study.
The Bonfils retromolar intubation fiberscope is a rigid endoscope designed to enable glottic visualization and facilitate intubation under endoscopic vision. Theoretically, avoiding direct-vision laryngoscopy and thus could produce less stimulation during intubation than the conventional direct laryngoscopic procedure. This prospective randomized study was designed to compare the effect of trac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 55 4 شماره
صفحات -
تاریخ انتشار 2008