Effect of sex on torque, recovery, EMG, and MMG responses to fatigue
نویسندگان
چکیده
OBJECTIVE The purpose of the present investigation was to examine the effect of sex on maximal voluntary isometric contraction (MVIC) torque and the EMG and MMG responses as a result of fatiguing, intermittent, submaximal (65% of MVIC), isometric elbow flexion muscle contractions. METHODS Eighteen men and women performed MVIC trials before (pretest), after (posttest), and 5-min after (5-min recovery) performing 50 intermittent, submaximal isometric muscle contractions. Surface electromyographic (EMG) and mechanomyographic (MMG) signals were simultaneously recorded from the biceps brachii muscle. RESULTS As a result of the fatiguing workbout torque decreased similarly from pretest to posttest for both the men (24.0%) and women (23.3%). After 5-min of recovery, torque had partially recovered for the men, while torque had returned to pretest levels for the women. For both sexes, from pretest to posttest EMG mean power frequency and MMG amplitude decreased, but returned to pretest levels after 5-min of recovery. CONCLUSIONS In the present study, there were sex-related differences in muscle fatigue that were not associated with the EMG or MMG responses.
منابع مشابه
Muscle- and Mode-Specific Responses of the Forearm Flexors to Fatiguing, Concentric Muscle Actions
Background: Electromyographic (EMG) and mechanomyographic (MMG) studies of fatigue have generally utilized maximal isometric or dynamic muscle actions, but sportand work-related activities involve predominately submaximal movements. Therefore, the purpose of the present investigation was to examine the torque, EMG, and MMG responses as a result of submaximal, concentric, isokinetic, forearm fle...
متن کاملMMG and EMG responses during fatiguing isokinetic muscle contractions at different velocities.
The purpose of this study was to determine mechanomyographic (MMG) and electromyographic (EMG) responses of the superficial quadriceps muscles during repeated isokinetic contractions in order to provide information about motor control strategies during such activity, and to assess uniformity in mechanical activity (MMG) between the investigated muscles. Ten adults performed 50 maximal concentri...
متن کاملمعرفی روش استفاده از سیگنال مکانومیوگرام در ارزیابی عملکرد عضلات
Background and aims Recordings of electrical activity in the muscle and surface electromyography (EMG) have been widely used in the field of applied physiology. In parallel to recording of the EMG, the detectable low-frequency vibration signal generated by the skeletal muscle has been known and well documented. As the nature of the signal has been progressively revealed, the term of mec...
متن کاملMechanomyographic and electromyographic amplitude and frequency responses during fatiguing isokinetic muscle actions of the biceps brachii.
The purpose of this investigation was to examine the mechanomyographic (MMG) and electromyographic (EMG) amplitude and mean power frequency (MPF) patterns during fatiguing isokinetic muscle actions of the biceps brachii. Ten adults [three women (mean +/- SD age = 20 +/- 2 yrs) and seven men (mean +/- SD age = 23 +/- 3 yrs) ] volunteered to perform 50 consecutive maximal, concentric isokinetic m...
متن کاملElectromyographic and Mechanomyographic Time and Frequency Responses During Fatiguing, Submaximal, Isokinetic Muscle Actions of the Biceps Brachii
The purpose of the present investigation was to examine the time-course of changes in electromyographic (EMG) and mechanomyographic (MMG), time and frequency domain responses during repeated, submaximal, concentric, isokinetic, forearm flexion muscle actions. Twelve men (mean age ± SD = 22.6 ± 2.2 yrs; body weight = 84.0 ± 8.3 kg; height = 178.6 ± 8.3 cm) performed 50 repeated, submaximal (65% ...
متن کامل