3D Wiener Filtering to Reduce Reverberations in Ultrasound Image Sequences

نویسندگان

  • Nina Eriksson Bylund
  • Marcus Ressner
  • Hans Knutsson
چکیده

One of the most frequently occuring artifacts in ultrasound imaging is reverberations. These are multiple reflection echoes that result in ghost echoes in the ultrasound image. A method for reducing these unwanted artifacts using a three-dimensional (3D) Wiener filter is presented. The Wiener filter is a global filter and produces an estimate of the uncorrupted signal by minimizing the mean square error between the estimate and the uncorrupted signal in a statistical sense. The procedure works as follows: In a graphic interface the operator is displayed an image sequence. The operator marks two areas in one of the images; one area which contains a typical reverberation artifact, and one area free from artifact. Using these areas to produce noise and signal estimates, a Wiener filter is created and applied to the sequence. The 3D Wiener filters display excellent selection capabilities, and the developed method significantly reduces the magnitude of the reverberation artifact in the tested sequences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reverberation Reduction Using 3d Wiener Filtering

One of the most common artifacts in ultrasound imaging is reverberations. These are multiple reflection echoes that register as coming from a deeper region than the depth of the interface that are causing them, and result in ghost echoes in the ultrasound image. A method to reduce these unwanted artifacts using a three dimensional (2D + time) Wiener filter has been developed. Two sequences of i...

متن کامل

A New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT

ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance.  In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...

متن کامل

Spatio-temporal Filtering of Ultrasound Image Sequences

A number of diseases result in reduced perfusion of the vital organs of the body. Measures of the blood flow in the small vessels (the perfusion) of these organs would contribute significantly to a clinical diagnosis. Myocardial contrast echocardiography is a rapidly developing technique for non-invasive ultrasound imaging of perfusion. The work presented in this thesis is related to the prepro...

متن کامل

Effect of Wiener-Helstrom Filtering Cascaded with Bacterial Foraging Optimization to Despeckle the Ultrasound Images

The diagnosing of disease using speckled ultrasound image is a very difficult task for doctors. The speckle noise not only hinders the visual information but also affect the segmentation process used in ultrasound image processing. Thus speckle noise suppression is necessary pre-processing task in order to maintain the diagnostic potential of ultrasound imaging. This paper proposes an efficient...

متن کامل

Denoising Of Intravascular Ultrasound Images: A Comparative Study

The major objective of the image Enhancement techniques is to emphasize & sharpen the features of images for better display & investigation. Medical images are affected by the Mixed Noise, which is the combination of Speckle & Gaussian Noise. Mixed Noise is an inherent property of Intravascular Ultrasound Imaging (IVUS) & it is generally tends to deteriorate the image quality, thereby reducing ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003