Nanoindentation of the insertional zones of human meniscal attachments into underlying bone.

نویسندگان

  • K N Hauch
  • M L Oyen
  • G M Odegard
  • T L Haut Donahue
چکیده

The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal body, allowing the menisci to assist in load transmission from the femur to the tibia. Clinically, tears and ruptures of the meniscal attachments and insertion to bone are rare. While it has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau, little is known about the material properties of meniscal attachments and the transition in material properties from the meniscus to subchondral bone. The objective of this study was to use nanoindentation to investigate the transition from meniscal attachment into underlying subchondral bone through uncalcified and calcified fibrocartilage. Nanoindentation tests were performed on both the anterior and posterior meniscal insertions to measure the instantaneous elastic modulus and elastic modulus at infinite time. The elastic moduli were found to increase in a bi-linear fashion from the external ligamentous attachment to the subchondral bone. The elastic moduli for the anterior attachments were consistently larger than those for the matching posterior attachments at similar indentation locations. These results show that there is a gradient of stiffness from the superficial zones of the insertion close to the ligamentous attachment into the deeper zones of the bone. This information will be useful in the continued development of successful meniscal replacements and understanding of fixation of the replacements to the tibial plateau.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time dependent properties of bovine meniscal attachments: stress relaxation and creep.

It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau [Chen, M.I., Branch, T.P., et al., 1996. Is it important to secure the horns during lateral meniscal transplantation? A cadaveric study. Arthroscopy 12(2), 174-181; Alhalki, M.M., et al., 1999. How thre...

متن کامل

Regional comparisons of nano-mechanical properties of the human meniscus; structure and function

Menisci are crescent shaped fibrocartilaginous structures which support load distribution of the knee. The menisci are specifically designed to fit the contour of the femoral condyles, aiding to disperse the stresses on the tibial plateau and in turn safeguarding the underlying articular cartilage. The importance of the meniscal superficial layer has not been fully revealed and it is suspected ...

متن کامل

Clinical Results of Meniscal Repair Using Submeniscal Horizontal Sutures

Background:  Parts of the implants placed over the meniscus during meniscal repair can wear down the cartilage in the contact zones and cause chronic synovitis. Placing horizontal sutures under the meniscus may overcome this potential hazard. The purpose of this prospective study was to evaluate the midterm results of arthroscopic meniscal repair using submeniscally placed out-in horizontal sut...

متن کامل

Geometry, time-dependent and failure properties of human meniscal attachments.

Meniscectomies have been shown to lead to osteoarthritis and the success of meniscal replacements remains questionable. It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau at the horn locations. To aid in the development of meniscal replacements, the obj...

متن کامل

Failure properties and strain distribution analysis of meniscal attachments.

The menisci are frequently injured due to both degeneration and traumatic tearing. It has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau. Therefore, the objectives of the current study were to (1) determine the failure properties of the meniscal horn attac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2009