Sequential hemodynamic assessment in aortic valve insufficiency in rats
نویسندگان
چکیده
OBJECTIVE: In animal models of aortic insufficiency, the right common carotid artery is typically used to damage valve leaflets; this strategy impedes subsequent assessments of left ventricular hemodynamics. The present study aimed to establish an alternative technique that would allow subsequent left ventricular catheterization to monitor sequential hemodynamics in rats with aortic insufficiency. METHOD: The right internal and external carotid artery branches were dissected. The internal branch was temporarily occluded. The external branch was also occluded, and the proximal, patent segment was catheterized. Via the catheter, ventricular hemodynamic evaluations were performed before and after incurring leaflet damage. The catheter was removed, and the right external branch was permanently ligated. The temporary right internal carotid occlusionwas released, and blood flowwas re-established. After four weeks, left ventricular hemodynamic measurements were performed from the right common carotid artery. RESULTS: Four weeks after the establishment of aortic insufficiency, left ventricular hemodynamic parameters showed a classic chronic hemodynamic pattern, similar to that observed in patients with chronic or compensated aortic insufficiency. Systolic blood pressure was elevated and pulse pressure was increased. CONCLUSION: This new method of carotid artery catheterization permitted two sequential, distinct hemodynamic measurements, in experimental model of aortic valve insufficiency.
منابع مشابه
Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملDoppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملANTIPHOSPHOLIPID ANTIBODY SYNDROME-A CASE OF AORTIC VALVE INSUFFICIENCY
A 31 year old woman was hospitalized for evaluation of aortic valve insufficiency and her present cardiac status. Clinical and paraclinical findings strongly suggested the presence of a collagen vascular inflammatory processprecisely, the antiphospholipid antibody syndrome (APS), with systemic lupus erythematosus as the underlying disease.
متن کاملINFECTIVE ENDOCARDITIS IN CHILDREN
A total of 14 cases of infective endocarditis (IE) in children aged 6 months to 10 years were seen from December 1987 to December 1992 at the pediatric unit of Ayatollah Taleghani Medical Center. The majority of patients (12 of 14) were between 5 and 10 years of age. Acyanotic congenital heart disease was known to preexist in 78.6% and rheumatic valvular heart disease in 21.4% of cases. Or...
متن کاملAssessment of Aortic Stenosis Severity by Cardiovascular Magnetic Resonance
Cardiovascular magnetic resonance (CMR) has become a valuable tool to corroborate aortic stenosis (AS) severity when echocardiography assessment is discordant. Moreover, CMR can provide useful complementary information about AS severity and hemodynamic markers. In particular, the use of advanced 4D flow CMR allows a comprehensive assessment of complex flow alterations produced by AS. This revie...
متن کامل