Background-based Delineation of Internal Tumor Volume in Static Positron Emission Tomography in a Phantom Study

نویسندگان

  • Yangchun Chen
  • Xiangrong Chen
  • Ji-an Liu
  • Fanyong Li
چکیده

OBJECTIVES Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. METHODS Three hollow models were filled with 55.0 kBq/mL fluorine-18 fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled with 5.9 kBq/mL 18F-FDG to characterize normal lung tissues as a phantom. The PET/CT images of the phantom were acquired at rest. Then, the barrel was moved periodically to simulate breathing while acquiring PET/CT data. Volume recovery coefficient (VRC) was applied to evaluate the accuracy of ITVs. For statistical analysis, paired t-test and analysis of variance were applied. RESULTS The VRCs ranged from 0.74 to 0.98 and significantly varied among gross tumor volumes for delineating ITV (P<0.01). In two-dimensional PET scans, the motion distance did not affect VRC (P>0.05), whereas VRC decreased with increasing distance in three-dimensional PET scans (P<0.05). CONCLUSION The threshold value (x+3×SD) had the potential to delineate the ITV of cancerous tissues, surrounded by lung tissues, particularly in two-dimensional PET images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Importance of defect detectability in Positron Emission Tomography imaging of abdominal lesions

Objective(s): This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. Methods: A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 mi...

متن کامل

Comparison of three image segmentation techniques for target volume delineation in positron emission tomography

Incorporation of positron emission tomography (PET) data into radiotherapy planning is currently under investigation for numerous sites including lung, brain, head and neck, breast, and prostate. Accurate tumor-volume quantification is essential to the proper utilization of the unique information provided by PET. Unfortunately,target delineation within PET currently remains a largely unaddresse...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016