Validity of the Handheld Dynamometer Compared with an Isokinetic Dynamometer in Measuring Peak Hip Extension Strength
نویسندگان
چکیده
PURPOSE To determine whether the handheld dynamometer (HHD) is an appropriate tool to assess and quantify peak hip extension strength in prone standing position by (1) evaluating the concurrent validity of the HHD versus an isokinetic dynamometer (IKD), (2) establishing the minimal detectable change (MDC), and (3) determining the validity of single-trial versus multi-trial measures. METHOD A convenience sample of 20 healthy adults was recruited for this cross-sectional study. Measures of peak hip extension strength were collected in prone standing position with both the HHD and the IKD and in supine position with the IKD. RESULTS Values of r were 0.37 for HHD versus IKD prone standing and 0.51 for HHD versus IKD supine. MDC was 14.8 Nm for the HHD, 25.6 Nm for IKD prone standing, and 41.5 Nm for IKD supine. High correlations (r values of 0.92-0.94) were observed between trial 1 and the mean of three trials. CONCLUSIONS The HHD has moderate concurrent validity in measuring peak hip extension strength in the prone standing position in healthy adults. MDC for hip extension strength was lowest using the HHD. Single-trial values showed a high correlation with three-trial mean values.
منابع مشابه
Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subj...
متن کاملMeasuring seated hip extensor strength using a handheld dynamometer: an examination of the reliability and validity of the protocol
[Purpose] The purpose of this study was to examine the reliability and validity of measurements of hip extensor muscle strength using a handheld dynamometer (HHD) with subjects in a sitting position. In doing so, we also aimed to establish a modified method of measurement for patients with flexion contractures in the trunk and lower extremities. [Subjects and Methods] In 20 healthy males, hip e...
متن کاملReliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
OBJECTIVE To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. METHODS Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee exten...
متن کاملClinimetric properties of hip abduction strength measurements obtained using a handheld dynamometer in individuals with a lower extremity amputation
INTRODUCTION Suitable handheld dynamometer (HHD)-techniques to test hip abduction strength in individuals with a lower extremity amputation, irrespective of their amputation level are absent. The aim of this study was to optimise a HHD-technique and to test its reproducibility and validity. METHODS This study involved three phases, in which two techniques were evaluated. Both HHD-techniques u...
متن کاملEffects of examiner strength on reliability of hip-strength testing using a handheld dynamometer.
CONTEXT Hip-muscle impairments are associated with a variety of lower-extremity dysfunctions. Accurate assessment in the clinical setting can be challenging due to the strength of hip muscles relative to examiner strength. OBJECTIVE To examine the influence of examiner strength and technique on manual hip-strength testing using a handheld dynamometer. DESIGN Repeated measures. SETTING Res...