Bacterial contamination of platelet concentrates stored at 20 ° C
نویسنده
چکیده
In a series of important studies Murphy and his colleagues demonstrated that the preparation and storage of platelet-rich plasma and platelet concentrates at 22°C rather than 4°C improved their life span in vivo (Murphy and Gardner, 1969; Murphy, Sayar, and Gardner, 1970). The potential clinical relevance of this finding has been confirmed by Handin and Valeri (1971), and it is likely that this approach to platelet procurement and storage will be widely instituted. Although Murphy and Gardner (1969) drew attention to the possible danger of bacterial proliferation if a storage temperature of 22°C was introduced, they concluded that in practice it was likely to be minimal. This conclusion has been supported by the findings of Silver, Sonnenwirth, and Beisser (1970) and of Katz and Tilton (1970) who found no evidence of bacterial contamination in 140 platelet concentrates stored at room temperature for up to 96 hours. Other studies by Buchholtz, Young, Friedman, Reilly, and Mardiney (1971) indicated an estimated minimal contamination rate of 24% in individual platelet concentrates stored at room temperature. However, the magnitude of bacterial contamination was not recorded as quantitative techniques were not used, but it was assumed to be low as the overall frequency of clinically significant infections or reactions appeared to be quite small. In view of the significant discrepancies between these three studies, the clinical importance of the administration of contaminated blood products to a large proportion of patients who are likely to be immunosuppressed, and the knowledge that certain bacteria cause aggregation of platelets (Clawson and White, 1971), a study of the bacterial contamination of platelet concentrates prepared and stored at room
منابع مشابه
402 INITIAL PLATELET CONCENTRATE CULTURE Margaret Cunningham
In a series of important studies Murphy and his colleagues demonstrated that the preparation and storage of platelet-rich plasma and platelet concentrates at 22°C rather than 4°C improved their life span in vivo (Murphy and Gardner, 1969; Murphy, Sayar, and Gardner, 1970). The potential clinical relevance of this finding has been confirmed by Handin and Valeri (1971), and it is likely that this...
متن کاملThe effect of platelet concentrate storage temperature on adenine nucleotide metabolism.
The effect of platelet concentrate storage temperature (4 degrees C versus 22 degrees C) on platelet adenine nucleotide metabolism was studied. In general, levels of platelet ATP and ADP, the release reaction, and the metabolis nucleotide pool were best preserved for 72 hr by storage of concentrates at 4 degrees C. Storage of concentrates for 72 hr at 22 degrees C was occasionally associated wi...
متن کاملThe surface markers and survival rate of platelets during storage at 4°C: The influence of sodium octanoate
Background: Storage of platelet concentrates (PCs) at room temperature (20-24°C) limits its storage time to 5 days due to the destructive effects of platelet storage lesion (PSL) and bacterial contamination. Although prolonged storage of platelets (PLTs) at 4°C reduces the likelihood of bacterial contamination and PSL levels, it is accompanied by an increase in the clearance rate and changes in...
متن کاملPlatelet Septic Transfusion Reactions in Patients With Hemato-Oncological Diseases
Background & Objective: Bacterial, contamination of blood components are a significant risk for transfusion reactions. Inherently, platelet concentrates (PCs) are vulnerable to bacterial contamination, due to the storage condition of processed PCs at room temperature, which provide very suitable conditions for the proliferation of microorganisms....
متن کاملpH changes caused by bacterial growth in contaminated platelet concentrates.
While platelet concentrates are stored at room temperature, lactic and other acids are produced and the pH decreases as the buffering capacity of the plasma is exhausted. Platelet viability will be compromised if the pH decreases to pH 6.0 and below. Similarly, a pH decrease can be produced also by bacterial contamination if the organisms produce acid as an end product. Thus the determination o...