Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction

نویسندگان

  • Gunnar T.R. Hischebeth
  • Sascha Gravius
  • Johanna K. Buhr
  • Ernst Molitor
  • Matthias D. Wimmer
  • Achim Hoerauf
  • Isabelle Bekeredjian-Ding
  • Thomas M. Randau
چکیده

In orthopedic patients, foreign body-associated infections, especially periprosthetic joint infections (PJIs), are a devastating complication of arthroplasty. Infection requires complex treatment, may result in long hospitalization and causes considerable costs. Multiple surgical revisions can be necessary in these patients, with a loss in function as well as in quality of life. The routine preoperative diagnostics include blood examination for C-reactive protein (CRP) and other biomarkers, as well as joint aspirate analysis for cell count, differentiation, and culture. Intraoperative specimens for histology and microbiology are also standard procedure. The microbiological examination of removed implants with sonication, in combination with the implementation of molecular biology techniques in microbiology, represent two novel techniques currently employed to enhance the differential diagnostics of PJI. We present here the step-wise procedure of analyzing joint aspirate and sonication fluid, using a cartridge-based multiplex polymerase chain reaction (PCR) system. Results were matched against conventional cultures and consensus criteria for PJI. Conventional microbiological cultures from tissue biopsies, joint aspirate and sonication fluid showed a sensitivity of 66.7%, 66.7%, and 88.9%, respectively, and a specificity of 82.3%, 54.6%, and 61.5%, respectively. The PCR diagnostic of the sonication fluid and the joint fluid showed a sensitivity of 50.0% and 55.6%, respectively, and both a specificity of 100.0%. Both PCR diagnostics combined had a sensitivity of 66.7% and a specificity of 100.0%. The multiplex PCR therefore presents a rapid diagnostic tool with moderate sensitivity but high specificity in diagnosing PJI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision total knee arthroplasty: infection should be ruled out in all cases.

We hypothesized that some aseptic revision total knee arthroplasty failures are indeed caused by occult infection. This prospective study recruited 65 patients undergoing revision total knee arthroplasty. The mean follow-up period was 19 months. Collected synovial fluid was analyzed by Ibis T5000 biosensor (Abbott Molecular Inc, Ill; a multiplex polymerase chain reaction technology). Cases were...

متن کامل

Comparison of cultures and 16S rRNA sequencing for identification of bacteria in two-stage revision arthroplasties: preliminary report

BACKGROUND The use of a prefabricated spacer in two-stage revision arthroplasty remains one of the few surgery strategies for infected-joint arthroplasty treatment, despite the many unidentified microorganisms in the infected joint replacements reported in some recent studies. The aim of this prospective survey was to investigate if the sonication followed by polymerase chain reaction (PCR) can...

متن کامل

Detection Of Toxoplasma Gondii and Human Cytomegalovirus DNA in Blood from Transplant Recipients Using Multiplex Nested Polymerase Chain Reaction

Evidences from many studies suggested a polymerase chain reaction (PCR) as a valuable method for diagnosing infectious disease in the transplant recipients. We used this method for detection of Toxoplasma, gondii and human cytomegalovirus in blood specimens from patients after bone marrow or kidney transplantation. DNA of both infectious agents were detected using two separate sets of nested pr...

متن کامل

BIOMED-2 multiplex immunoglobulin/T-cell receptor polymerase chain reaction protocols can reliably replace Southern blot analysis in routine clonality diagnostics.

To establish the most sensitive and efficient strategy of clonality diagnostics via immunoglobulin and T-cell receptor gene rearrangement studies in suspected lymphoproliferative disorders, we evaluated 300 samples (from 218 patients) submitted consecutively for routine diagnostics. All samples were studied using the BIOMED-2 multiplex polymerase chain reaction (PCR) protocol. In 176 samples, S...

متن کامل

Real-time Pcr without Dna Extraction: a Modification for More Rapid Detection of Bacteria on Orthopaedic Implants

Introduction Infection is one of the most important causes of joint implant failure. The polymerase chain reaction (PCR) is a sensitive way to test for bacteria, but most PCR procedures take too long to provide results during a revision arthroplasty operation. For example, we have described the sensitivity and specificity of real-time PCR combined with ultrasonication of retrieved implants to d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2017