A new correlation method for high sensitivity current noise measurements.
نویسندگان
چکیده
The properties of a differential transconductance amplifier coupled with a four channel measurement system are exploited in order to reach a very high sensitivity in current noise measurements. In particular, it is demonstrated that, in proper conditions, the noise contributions coming from the active and passive devices that make up the transresistance amplifier can be virtually eliminated. Moreover, the proposed measurement method allows the evaluation of the impedance of the device under test from noise measurement data. Actual measurement results are also reported that demonstrate the effectiveness of the proposed approach.
منابع مشابه
A Novel Data Compression Technique for 420 Ma Current Loop Transmitters
This paper presents a new data compression method for current loop transmitters. In this method, the 4-20 mA current domain is divided into some equal pieces that are used for distinct data domain with a constant relative resolution, resulting in widening the signal span. This technique eliminated the need for high resolution ADC’s or DAC’s in communication of 4-20mA current loop signals. Furth...
متن کاملFour channels cross correlation method for high sensitivity current noise measurements
We demonstrate how it is possible to increase the sensitivity of current noise measurement systems by exploiting the properties of a differential transconductance amplifier coupled with a four channels measurement system. In particular, it is demonstrated that, in proper conditions and by a proper elaboration of the acquired signals, the noise contribution coming from the active and passive dev...
متن کاملComparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar
Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of rado...
متن کاملThe Sensitivity of Central Bank Independence Measurements to Inflation in Iran: A New Approach
The purpose of this study is finding the sensitivity of central bank independence measurements on its impact on inflation in Iran. To this aim different measurements of the central bank independence were calculated using the indices of Grilli et al. (1991), Cukierman et al. (1992), Mathew (2006) and Dumiter (2009) for the period 1961-2012 . Although results of correlation between CBI index and ...
متن کاملA Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates
Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 78 11 شماره
صفحات -
تاریخ انتشار 2007