Earlier detection of myocardial injury in a preliminary evaluation using a new troponin I assay with improved sensitivity.

نویسندگان

  • Stacy E F Melanson
  • David A Morrow
  • Petr Jarolim
چکیده

Cardiac troponins are important biochemical markers for defining the presence of myocardial injury. However, limitations in troponin testing exist, including the relatively late increase in troponin after onset of ischemia. We therefore evaluated a more sensitive troponin assay for detection of myocardial injury in "early presenters." Discarded serial specimens were obtained from 103 patients who had a negative cardiac troponin I (cTnI) result followed by a positive cTnI result. Results were obtained using our current cTnI method and a new more sensitive assay, TnI-Ultra (Siemens Medical Solutions, Diagnostics Division, Tarrytown, NY). Medical records were reviewed to determine the clinical diagnosis. Precision studies yielded a 10% coefficient of variation at the diagnostic cut points for cTnI (0.10 ng/mL [0.10 microg/L]) and TnI-Ultra (0.04 ng/mL [0.04 microg/L]). TnI-Ultra was positive before cTnI in 66 (64.1%) of 103 cases. We conclude that the more sensitive assay, TnI-Ultra, has better analytic performance and has the potential to detect myocardial injury earlier than the current cTnI assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

Analytic and clinical utility of a next-generation, highly sensitive cardiac troponin I assay for early detection of myocardial injury.

BACKGROUND Improvements in cardiac troponin (cTn) assays have increased the rapidity with which clinicians can identify patients with changing cTn concentrations (rise or fall) indicative of acute myocardial injury. The aim of the present study was to characterize a new, high-sensitivity cTnI (hs-cTnI) assay and examine whether increased sensitivity can result in still earlier detection of evol...

متن کامل

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

The most sensitive double-marker method of cardiac isoenzymes of creatinine kinase, troponin I, and myoglobin in different time periods for diagnosing acute myocardial infarction

  Purpose: Myocardial infarction is among the most common diagnoses in patients admitted   to hospitals in western countries, and its rapid diagnosis is of utmost importance. This study   was conducted to determine the most sensitive double-marker cardiac isoenzyme of creatinine   kinase, troponin I, and myoglobin for diagnosing acute myocardial infarction.   Materials and Methods: This was an ...

متن کامل

High-sensitivity Cardiac Troponin: From Theory to Clinical Practice Troponina cardiaca ultrasensible: de la teorı́a a la práctica clı́nica

Since 2000, cardiac troponin (cTn) has been the recommended biomarker for the evaluation of patients with a possible diagnosis of acute myocardial infarction (AMI). Most of the cTn immunoassays currently in use lack the analytical sensitivity to accurately measure the upper reference limit (URL), ie, the 99th percentile reference value, which is the guideline-mandated cutoff value for myocardia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 128 2  شماره 

صفحات  -

تاریخ انتشار 2007