Result of Modular Necks in Primary Total Hip Arthroplasty with a Average Follow-up of Four Years

نویسندگان

  • Jemin Yi
  • Kye Young Han
  • Young Jun Nam
  • Keun Woo Kim
چکیده

PURPOSE This study aimed to investigate the outcomes of modular neck-utilization in primary total hip arthroplasty (THA). MATERIALS AND METHODS Thirty patients (34 hips) who had modular stem THA between April 2011 and January 2013 were evaluated. There were 19 men and 11 women with a mean age of 61.2 years at the time of surgery. There were 20 cases of osteonecrosis of femoral head, 7 cases of osteoarthritis, 6 cases of femur neck fracture, and 1 case of rheumatoid arthritis. No patients presented with anatomical deformity of hip. Patients were operated on using a modified Watson-Jones anterolateral approach. All patients underwent clinical and radiological follow-up at 6 weeks, 3, 6, and 12 months, and every year postoperatively. The mean duration of follow-up was 48.2 months (range, 39 to 59 months). RESULTS The average Harris hip score improved from 63.7 to 88.1 at the final follow-up. Radiographically, mean acetabular cup inclination was 45.3°(range, 36°-61°) and anteversion was 21.7°(range, 11°-29°). All were neutral-positioned stems except 5 which were varus-positioned stems. In only 3 cases (8.8%), varus or valgus necks were required. A case of linear femoral fracture occurred intraoperatively and 1 case of dislocation occurred at postoperative 2 weeks. No complications at modular junction were occurred. CONCLUSION Our study shows that the use of modular necks had favorable clinical and radiographic results. This suggests that the use of modular neck in primary THA without anatomical deformity is safe at a follow-up of 39 months.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Effect of Femoral Stem Modular Neck’s Material on Metal Ion Release

Background In recent decades, the popularity of modular necks in total hip arthroplasty (THA) has increased since modular necks offer the potential to restore the patient's native anatomy, and thus improve stability. Unfortunately, modular necks are associated with higher complication rates, including implant fracture and modular junction corrosion with adverse local tissue reaction to metal de...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

A stature-specific concept for uncemented, primary total hip arthroplasty

BACKGROUND AND PURPOSE Variations in hip anatomy limit the femoral canal fit of standard uncemented hip stems. In addition, there are still issues with leg length discrepancy and offset reconstruction, potentially resulting in impingement, dislocation, and wear. Modular stems with different shapes for femoral canal fit and multiple neck options may improve the outcome and reduce complications. ...

متن کامل

Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis

Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016