Validation With Simultaneous Cardiac Catheterization
نویسندگان
چکیده
Background. The instantaneous pressure gradient between the left ventricle and left atrium during systole can be calculated from the mitral regurgitation Doppler velocity curve. The purpose of our study was to determine the accuracy of measuring the time constant of relaxation (TAU) derived from the Doppler mitral regurgitation signal by comparing it with simultaneous high-fidelity left ventricular pressure measurements in humans. Methods and Resus. Twenty-five patients had continuous-wave Doppler mitral regurgitation recordings performed with simultaneous high-fidelity left ventricular pressure measurements. Fifteen of these patients had measurements of six to eight beats at various RR intervals. Doppler velocity curves were converted to left ventricular pressure curves by different methods through application of the modified Bernoulli equation at 3-msec intervals. The correlation between catheter-derived and Doppler-derived TAU was best when a zero asymptote and knowledge of the left ventricular end-diastolic pressure were used. A less optimal but acceptable method used the addition of 20 mm Hg to the Doppler-derived ventriculoatrial gradient. Use of a nonzero asymptote for calculation of TAU yielded poor correlation between catheter and Doppler measurements. The correlation of percentage change in Doppler-derived TAU plotted against percentage change in catheter-derived TAU was poor. Conclusions. The descending limb ofthe Doppler-derived mitral regurgitation velocity signal can be used
منابع مشابه
Relationship between Neutrophil-to-lymphocyte Ratio and the Severity of Coronary Artery Disease in Patients Undergoing Cardiac Catheterization
Introduction: Neutrophil-to-lymphocyte ratio (NLR) is considered as an independent predictor of long-term prognosis in the individual patients with coronary artery disease (CAD). This study sought to assess the relationship between NLR and CAD severity in Iranian patients undergoing cardiac catheterization.Material and Methods: This prospective study was conducted on 500 patients with acute cor...
متن کاملValidation of the beat to beat measurement of blood velocity in the human ascending aorta by a new high temporal resolution Doppler ultrasound spectral analyser.
OBJECTIVE To develop and validate a high temporal resolution spectral analysis system for Doppler measurements of blood velocity in the ascending aorta. DESIGN An observational laboratory and clinical study comparing Doppler velocity-based measurements with fluid collection, electromagnetic flow catheters and probes, and thermodilution. SETTING Tertiary referral cardiology unit and cardiac ...
متن کاملThe Effect of Body Position and Early Ambulation on Comfort, Bleeding, and Ecchymosis After Diagnostic Cardiac Catheterization
Background: Diagnostic cardiac catheterization is a common procedure in coronary artery disease. Patients’ movement and activities are limited because of potential risks; therefore, they need bed rest. The current study aimed at investigating the impacts of changes in body position and earlier ambulation on comfort, bleeding, and ecchymosis after the diagnostic cardiac catheterization. M...
متن کاملMeasurement of left ventricular diameter in the dog by cardiac catheterization. Validation and physiologic meaningfulness of an ultrasonic technique.
A cylindrical ultrasonic transducer on a catheter tip lodged in the cleft between the free wall of the right ventricle and the interventricular septum provides an easily measured echo from the posteroinferior left ventricular epicardial surface. The sonic path represents a diameter of the left ventricle at approximately its largest cross-sectional area. Experiments in six dogs demonstrated that...
متن کاملSimultaneous ramp right heart catheterization and echocardiography in a ReliantHeart left ventricular assist device
Many clinicians caring for patients with continuous flow left ventricular assist devices (CF-LVAD) use ramp right heart catheterization (RHC) studies to optimize pump speed and also to troubleshoot CF-LVAD malfunction. An investigational device, the ReliantHeart Heart Assist 5 (Houston, TX), provides the added benefit of an ultrasonic flow probe on the outflow graft that directly measures flow ...
متن کاملبررسی تاثیر تماس پوستی پیاز بر احتباس حاد ادراری بیماران مرد پس از کاتتریسم قلبی
Background and Aim: Acute urinary retention is an acute emergency identified by inability to void and also lower abdominal pain. This problem generally occurs following surgery or cardiac catheterization and needs to be solved through urinary catheterization, a procedure that raises the risk of urinary tract infections. Therefore, alternative ways of relieving urinary retention, preferably no...
متن کامل