Comparison of Inter Subject Variability and Reproducibility of Whole Brain Proton Spectroscopy
نویسندگان
چکیده
The aim of these studies was to provide reference data on intersubject variability and reproducibility of metabolite ratios for Choline/Creatine (Cho/Cr), N-acetyl aspartate/Choline (NAA/Cho) and N-acetyl aspartate/Creatine (NAA/Cr), and individual signal-intensity normalised metabolite concentrations of NAA, Cho and Cr. Healthy volunteers underwent imaging on two occasions using the same 3T Siemens Verio magnetic resonance scanner. At each session two identical Metabolic Imaging and Data Acquisition Software (MIDAS) sequences were obtained along with standard structural imaging. Metabolite maps were created and regions of interest applied in normalised space. The baseline data from all 32 volunteers were used to calculate the intersubject variability, while within session and between session reproducibility were calculated from all the available data. The reproducibility of measurements were used to calculate the overall and within session 95% prediction interval for zero change. The within and between session reproducibility data were lower than the values for intersubject variability, and were variable across the different brain regions. The within and between session reproducibility measurements were similar for Cho/Cr, NAA/Choline, Cho and Cr (11.8%, 11.4%, 14.3 and 10.6% vs. 11.9%, 11.4%, 13.5% and 10.5% respectively), but for NAA/Creatine and NAA between session reproducibility was lower (9.3% and 9.1% vs. 10.1% and 9.9%; p <0.05). This study provides additional reference data that can be utilised in interventional studies to quantify change within a single imaging session, or to assess the significance of change in longitudinal studies of brain injury and disease.
منابع مشابه
Reproducibility of Neurochemical Profile Quantification in Pregenual Cingulate, Anterior Midcingulate, and Bilateral Posterior Insular Subdivisions Measured at 3 Tesla
The current report assessed measurement reproducibility of proton magnetic resonance spectroscopy at 3 Tesla in the left and right posterior insular, pregenual anterior cingulate, and anterior midcingulate cortices. Ten healthy male volunteers aged 21-30 years were tested at four different days, of which nine were included in the data analysis. Intra- and inter-subject variability of myo-inosit...
متن کاملReproducibility of quantitative structural and physiological MRI measurements
INTRODUCTION Quantitative longitudinal magnetic resonance imaging and spectroscopy (MRI/S) is used to assess progress of brain disorders and treatment effects. Understanding the significance of MRI/S changes requires knowledge of the inherent technical and physiological consistency of these measurements. This longitudinal study examined the variance and reproducibility of commonly used quantita...
متن کاملSpatial variability and reproducibility of GABA‐edited MEGA‐LASER 3D‐MRSI in the brain at 3 T
The reproducibility of gamma-aminobutyric acid (GABA) quantification results, obtained with MRSI, was determined on a 3 T MR scanner in healthy adults. In this study, a spiral-encoded, GABA-edited, MEGA-LASER MRSI sequence with real-time motion-scanner-instability corrections was applied for robust 3D mapping of neurotransmitters in the brain. In particular, the GABA+ (i.e. GABA plus macromolec...
متن کاملReproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content.
PURPOSE To investigate reproducibility of proton magnetic resonance spectroscopy ((1)H-MRS) to measure hepatic triglyceride content (HTGC). MATERIALS AND METHODS In 24 subjects, HTGC was evaluated using (1)H-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of (1)H-MRS in subjects with fatty liver. We also studied within liver variability and within day reproduc...
متن کاملComparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کامل