A Nernstian Biosupercapacitor

نویسندگان

  • Dmitry Pankratov
  • Felipe Conzuelo
  • Piyanut Pinyou
  • Sabine Alsaoub
  • Wolfgang Schuhmann
  • Sergey Shleev
چکیده

We propose the very first "Nernstian biosupercapacitor", a biodevice based on only one redox polymer: poly(vinyl imidazole-co-allylamine)[Os(bpy)2 Cl], and two biocatalysts. At the bioanode PQQ-dependent glucose dehydrogenase reduces the Os3+ moieties at the polymer to Os2+ shifting the Nernst potential of the Os3+ /Os2+ redox couple to negative values. Concomitantly, at the biocathode the reduction of O2 by means of bilirubin oxidase embedded in the same redox polymer leads to the oxidation of Os2+ to Os3+ shifting the Nernst potential to higher values. Despite the use of just one redox polymer an open circuit voltage of more than 0.45 V was obtained during charging and the charge is stored in the redox polymer at both the bioanode and the biocathode. By connecting both electrodes via a predefined resistor a high power density is obtained for a short time exceeding the steady state power of a corresponding biofuel cell by a factor of 8.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction to Spectrophotometric Calibration of pH Electrodes in Seawater Using Purified m-Cresol Purple

This work examines the use of purified meta-cresol purple (mCP) for direct spectrophotometric calibration of glass pH electrodes in seawater. The procedures used in this investigation allow for simple, inexpensive electrode calibrations over salinities of 20-40 and temperatures of 278.15-308.15 K without preparation of synthetic Tris seawater buffers. The optimal pH range is ∼7.0-8.1. Spectroph...

متن کامل

Miniature Nernstian oxygen sensor for deposition and growth environments

A miniature Nernstian-type oxygen sensor employing an ionically conducting stabilized zirconia solid electrolyte and an embedded internal reference electrode is developed and is tested in the temperature range 275– 425 °C. It is intended for in situ monitoring of oxygen content in deposition and growth environments. Advantages of this sensor are in situ generation of the Ni/NiO two phase intern...

متن کامل

Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

متن کامل

A simple, inexpensive method for teaching how membrane potentials are generated.

We have developed a simple laboratory exercise that uses an inexpensive dialysis membrane (molecular weight cutoff = 100) to illustrate the generation of membrane potentials (Vm) across plasma membranes of animal cells. A piece of membrane approximately 2.0 cm2 is mounted in an Ussing-like chamber. One chamber half is designated cytosol and the other half external. Chamber sidedness helps stude...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2016