Glycoprotein IIb/IIIa antagonist FK633 could not prevent neointimal thickening in stent implantation model of canine coronary artery.

نویسندگان

  • Y Ueda
  • M Kitakaze
  • M Imakita
  • H Ishibashi-Ueda
  • T Minamino
  • H Asanuma
  • T Ozaki
  • E Imamura
  • T Kuzuya
  • M Hori
چکیده

The platelet glycoprotein (GP) IIb/IIIa receptor antagonist appears to reduce the need for revascularization after coronary angioplasty. However, since the effect of GP IIb/IIIa receptor antagonist on the in-stent neointimal thickening has not been clarified, we examined it in the canine model. The beagle dogs were assigned to the control (n=7) or the GP IIb/IIIa receptor antagonist FK633 group (n=7). FK633 was administered by subcutaneous osmotic pumps (0.2 mg. kg-1. h-1) and an intravenous bolus injection (1 mg/kg) before stenting. A coil stent was implanted in the left circumflex coronary arteries. The platelet aggregation capability was significantly (<5%) and consistently reduced by FK633 except for the mild elevation (10% to 30%) on the next day of stenting. Hearts were excised 3 months after stent implantation. The area of intima and media and the area stenosis were obtained from the sections of the stented arteries. The area of intima and media and the area stenosis (1.3+/-0.2 mm2, 41.8+/-7.5% and 1.3+/-0.2 mm2, 33.9+/-6.7% in the FK633 and the control group, respectively) were not different between the groups. We conclude that, although GP IIb/IIIa antagonist FK633 prevented the platelet aggregation significantly and consistently, it could not prevent the neointimal thickening after stent implantation in canine coronary artery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining prognosis early after a myocardial infarction.

[1] Serruys PW, de Jaegere P, Kiemeneij F et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994; 331: 489–95. [2] Topol EJ, Leya F, Pinkerton CA et al. A comparison of directional atherectomy with coronary angioplasty in patients with coronary artery disease. The CAVEAT Study Group...

متن کامل

Nonpeptide glycoprotein IIb/IIIa inhibitors. 15. Antithrombotic efficacy of L-738,167, a long-acting GPIIb/IIIa antagonist, correlates with inhibition of adenosine diphosphate-induced platelet aggregation but not with bleeding time prolongation.

The nonpeptide platelet glycoprotein IIb/IIIa antagonist, L-738, 167, was characterized in dog and nonhuman primate. In an anesthetized canine model of coronary artery electrolytic lesion, L-738,167 elicited dose-dependent (3, 4, 4.5 and 5 micrograms/kg i.v.) decreases in incidence of occlusion, reductions in thrombus mass and elevations in bleeding time. Antithrombotic efficacy correlated with...

متن کامل

Novel Strategies in Anti-Platelet Treatment for Coronary Artery Disease

Treatment with oral anti-platelet agents constitutes a cornerstone in the therapy of coronary artery disease. Coronary angioplasty and stent implantation improved the therapy of coronary artery disease and especially the treatment of acute myocardial infarction. Implementation of glycoprotein IIb/IIIa inhibition further advanced anti-platelet therapy as a central component in the treatment of a...

متن کامل

Prevention of thrombosis and rethrombosis and enhancement of the thrombolytic actions of recombinant tissue-type plasminogen activator in the canine heart by DMP728, a glycoprotein IIb/IIIa antagonist.

1. We studied DMP728, a non-peptide glycoprotein (GP) IIb/IIIa receptor antagonist, for prevention of coronary artery thrombosis or rethrombosis in a chronic canine model subjected to arterial injury. 2. In protocol I, DMP728 (1.0 mg kg-1, i.v., n = 8) or saline (n = 8) was administered and a 150 microA anodal current was applied to the intimal surface of the left circumflex coronary artery (LC...

متن کامل

Monitoring platelet GPIIb/IIIa antagonist therapy.

P latelet GP IIb/IIIa receptor antagonist therapy with abciximab (ReoPro), the Fab fragment of a mouse/ human chimeric version of the murine 7E3 antibody, is currently used to prevent ischemic complications of percutaneous coronary interventions in select cases, and the efficacy and safety of abciximab for other related indications are under study. A number of low-molecular-weight GP IIb/IIIa a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arteriosclerosis, thrombosis, and vascular biology

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 1999