Neutron Depolarization Studies of Pd-Ni-Fe-P alloy
نویسندگان
چکیده
Bulk metallic glasses based on the quaternary alloy Pd-Ni-Fe-P exhibit interesting phase behavior depending on temperature and applied magnetic field. Previous work has suggested that a range of magnetic phases including paramagnetic, superparamagnetic, ferromagnetic and spin glass can be observed in this system. We have applied one dimensional neutron depolarization to explore the correlation of magnetic moments in Pd40Ni22.5Fe17.5P20 alloy as a function of temperature and applied magnetic field. The results provided evidence for correlation lengths of ~ 200 Å. The nature of the correlations and the formation mechanism of the induced ferromagnetic phase are discussed.
منابع مشابه
SANS study of phase decomposition in Fe-Cu alloy added by Ni and Mn
Small-angle neutron scattering ( SANS ) measurements were mainly carried out in order to investigate the structure change during early stage of phase decomposition in Fe-Cu-Ni-Mn quaternary alloy. The fact that the nuclear Guinier radius becomes larger than the magnetic one beyond about 2 nm is attributed to the formation of segregated layer enriched by Ni and Mn around fcc copper-rich precipit...
متن کاملFerromagnetic shape memory alloys: Alternatives to Ni–Mn–Ga
This paper intends to review the state-of-the-art in the field of ferromagnetic shape memory alloys different than Ni–Mn–Ga, developed in the ast years. It starts with the effects of additions of different fourth elements to Ni–Mn–Ga and continues with the review of other Heusler (or B2) i-based and Co-based alloy systems, like Ni–Mn–X, Ni–Fe–Ga, Co–Ni–Al and Co–Ni–Ga alloys. Finally, ferromagn...
متن کاملEffects of metal combinations on cytotoxicity evaluation using a dynamic extraction method.
The effects of metal combinations on cytotoxicity were examined following dynamic extraction by freely gyrating two spherical metals in a glass vessel. The cell viabilities of an Au alloy, a Ag-Pd-Au alloy and Ti were little affected by combinations among three metals. Cell viability ranged between 60 and 80% when precious alloys were in combination with Co-Cr or Ni-Cr alloys. Ti showed a clear...
متن کاملEvaluation of the adaptation interface of one-piece implant-supported superstructures obtained in Ni-Cr-Ti and Pd-Ag alloys.
Several formulations of alternative alloys have been proposed for the substitution of gold-based alloys used in Dentistry. Recently, a Ni-Cr-Ti-based alloy has been introduced. The purpose of this work was to verify the marginal adaptation obtained with one-piece superstructures for implant-supported prostheses obtained in Ni-Cr-Ti alloy, compared to a semi-noble alloy Pd-Ag. Eight superstructu...
متن کاملAssessment of secondary neutron dose due to dental restorations in head and neck radiation therapy
Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...
متن کامل