Evaluation of a pulsed xenon ultraviolet disinfection system to decrease bacterial contamination in operating rooms

نویسندگان

  • Lynn El Haddad
  • Shashank S. Ghantoji
  • Mark Stibich
  • Jason B. Fleming
  • Cindy Segal
  • Kathy M. Ware
  • Roy F. Chemaly
چکیده

BACKGROUND Environmental cleanliness is one of the contributing factors for surgical site infections in the operating rooms (ORs). To decrease environmental contamination, pulsed xenon ultraviolet (PX-UV), an easy and safe no-touch disinfection system, is employed in several hospital environments. The positive effect of this technology on environmental decontamination has been observed in patient rooms and ORs during the end-of-day cleaning but so far, no study explored its feasibility between surgical cases in the OR. METHODS In this study, 5 high-touch surfaces in 30 ORs were sampled after manual cleaning and after PX-UV intervention mimicking between-case cleaning to avoid the disruption of the ORs' normal flow. The efficacy of a 1-min, 2-min, and 8-min cycle were tested by measuring the surfaces' contaminants by quantitative cultures using Tryptic Soy Agar contact plates. RESULTS We showed that combining standard between-case manual cleaning of surfaces with a 2-min cycle of disinfection using a portable xenon pulsed ultraviolet light germicidal device eliminated at least 70% more bacterial load after manual cleaning. CONCLUSIONS This study showed the proof of efficacy of a 2-min cycle of PX-UV in ORs in eliminating bacterial contaminants. This method will allow a short time for room turnover and a potential reduction of pathogen transmission to patients and possibly surgical site infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is the pulsed xenon ultraviolet light no-touch disinfection system effective on methicillin-resistant Staphylococcus aureus in the absence of manual cleaning?

BACKGROUND Methicillin-resistant Staphylococcus aureus (MRSA) has been shown to survive on ambient surfaces for extended periods of time. Leftover MRSA environmental contamination in a hospital room places future patients at risk. Manual disinfection supplemented by pulsed xenon ultraviolet (PX-UV) light disinfection has been shown to greatly decrease the MRSA bioburden in hospital rooms. Howev...

متن کامل

Evaluation of a pulsed-xenon ultraviolet room disinfection device for impact on contamination levels of methicillin-resistant Staphylococcus aureus

BACKGROUND Healthcare-acquired infections with methicillin-resistant Staphylococcus aureus (MRSA) are a significant cause of increased mortality, morbidity and additional health care costs in United States. Surface decontamination technologies that utilize pulsed xenon ultraviolet light (PPX-UV) may be effective at reducing microbial burden. The purpose of this study was to compare standard man...

متن کامل

Infection Control & Hospital Epidemiology

How to cite this article: Michelle M. Nerandzic, Priyaleela Thota, Thriveen Sankar C., Annette Jencson, Jennifer L. Cadnum, Amy J. Ray, Robert A. Salata, Richard R. Watkins and Curtis J. Donskey Evaluation of a Pulsed Xenon Ultraviolet Disinfection System for Reduction of Healthcare-Associated Pathogens in Hospital Rooms. Infection Control & Hospital Epidemiology, Available on CJO 2015 doi:10.1...

متن کامل

Analysis of Bacterial Contamination in Anesthetic Equipments in Operation Room of Vali-E-Asr Hospital of Fasa Efficiency of Disinfection Methods

Background & Objectives: Anesthetic equipments could be one of the factors transmitting infection in a surgical operation. We could be prevent infection transmission to a great extend, by providing efficient methods of disinfection of anesthetic equipments. The purpose of the present research is to analyze the bacterial contamination in anesthetic equipment in operation rooms of Vali-e-Asr hosp...

متن کامل

318Is the Pulsed Xenon Ultraviolet Light No-Touch Disinfection System Effective on MRSA in the Absence of Manual Cleaning?

318. Is the Pulsed Xenon Ultraviolet Light No-Touch Disinfection System Effective on MRSA in the Absence of Manual Cleaning? Chetan Jinadatha, MD, MPH; Donna Brown, RN; Kimberly Sikes; Nagaraja Ganachari-Mallappa, PhD; Infectious Disease Division, Central Texas Veterans Health Care System, Temple, TX; Department of Medicine, Texas A&M University Health Science Center, College of Medicine, Bryan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017