The coherence spectrum. A quantitative discriminator of fibrillatory and nonfibrillatory cardiac rhythms.

نویسندگان

  • K M Ropella
  • A V Sahakian
  • J M Baerman
  • S Swiryn
چکیده

Previous work has suggested that a comparison of electrograms from two or more sites may best differentiate fibrillatory from nonfibrillatory rhythms. The coherence spectrum is a measure by which two signals may be compared quantitatively in the frequency domain. In the present study, the coherence spectrum was used to quantify the relation between spectral components of electrograms from two sites in either the atrium or ventricle during both fibrillatory and nonfibrillatory rhythms. Bipolar recordings of 35 rhythms from 20 patients were analyzed for coherence in the 1-59 Hz band. The 17 nonfibrillatory rhythms were sinus rhythm (six), paroxysmal supraventricular tachycardia (two), atrial flutter (four), and monomorphic ventricular tachycardia (five). The 18 fibrillatory rhythms were atrial fibrillation (12) and ventricular fibrillation (six). Nonfibrillatory rhythms exhibited moderate-to-high levels of coherence throughout the 1-59 Hz band, with peaks concentrated at the rhythm's fundamental frequency and its harmonics. Fibrillatory rhythms exhibited little coherence throughout the 1-59 Hz band, and harmonics were not evident. The mean magnitude-squared coherence (scale of 0 to 1) for the 1-59 Hz band ranged from 0.22 to 0.86 (mean +/- SD, 0.52 +/- 0.19) for nonfibrillatory rhythms and from 0.042 to 0.12 (0.067 +/- 0.021) for fibrillatory rhythms. Separation of fibrillatory and nonfibrillatory rhythms was possible whether signals were recorded by floating or fixed-electrode configurations. These findings indicate that comparison of two electrograms with magnitude-squared coherence measurements differentiates fibrillatory from nonfibrillatory rhythms. A recognition algorithm based on coherence spectra may provide a major variations in lead configuration.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cortical Activity During Postural Recovery in Response to Predictable and Unpredictable Perturbations in Healthy Young and Older Adults: A Quantitative EEG Assessment

Introduction: To investigate the effects of predictable and unpredictable external perturbations on cortical activity in healthy young and older adults. Methods: Twenty healthy older and 19 healthy young adults were exposed to predictable and unpredictable external perturbations, and their cortical activity upon postural recovery was measured using a 32-channel quantitative encephalography. Th...

متن کامل

Atrial fibrillatory rate and risk of stroke in atrial fibrillation.

AIMS In atrial fibrillation (AF), a relation between electrocardiogram (ECG) parameters such as fibrillatory wave amplitude and stroke has been sought with conflicting results. In this study, we tested the hypothesis that the atrial fibrillatory rate of surface ECG lead V1 is related to stroke risk and may consequently be helpful for identifying high-risk patients. METHODS AND RESULTS Atrial ...

متن کامل

A new approach to detect Life threatening cardiac arrhythmias using Sequential spectrum of Electrocardiogram signals

This study evaluates the discriminative power of sequential spectrum analysis of the short-term electrocardiogram (ECG) time series in separating normal and subjects with life threatening arrhythmias like, ventricular tachycardia/fibrillation (VT/VF). The raw ECG time series is transformed into a series of binary symbols and the binary occupancy or relative distribution of mono-sequences (i.e. ...

متن کامل

A new approach to detect Life threatening cardiac arrhythmias using Sequential spectrum of Electrocardiogram signals

This study evaluates the discriminative power of sequential spectrum analysis of the short-term electrocardiogram (ECG) time series in separating normal and subjects with life threatening arrhythmias like, ventricular tachycardia/fibrillation (VT/VF). The raw ECG time series is transformed into a series of binary symbols and the binary occupancy or relative distribution of mono-sequences (i.e. ...

متن کامل

The Effect of Rainfall Parameters on Runoff Using Wavelet Coherence Measure

In this research wavelet coherence measure is implemented for evaluating the relations and effect of rainfall parameters over many years on runoff fluctuations that is for testing proposed linkages between two time series. In this way, monthly Hydro climatological as 3 rainfall stations, one runoff in the outlet of Ardabil plain were used. The results illustrate that 8-12 and 8-16 month modes o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 1989