Voltage Flicker Real-time Detection Based on Recursive Degree Method
نویسنده
چکیده
Traditional flicker detection methods accurately extract the amplitude envelope as the premise, the complexity of large amount of computation. This paper presents a new real-time detection of voltage flicker method, analysis method with recursive frequency carrier signal frequency; use of the adjacent three-point sampling data, the frequency carrier signal frequency, sampling frequency voltage flicker waveform obtained by the current envelope size. Of harmonic pollution by noise or flicker between the signals, the low-pass filtering results are not affected. Simulation results show that: The method to directly detect flicker signal, the process is simple, computational load and real time, tracking performance, with a certain anti-noise and inter-harmonic interference suppression capability, suitable for real-time detection of voltage flicker.
منابع مشابه
Online Fault Detection and Isolation Method Based on Belief Rule Base for Industrial Gas Turbines
Real time and accurate fault detection has attracted an increasing attention with a growing demand for higher operational efficiency and safety of industrial gas turbines as complex engineering systems. Current methods based on condition monitoring data have drawbacks in using both expert knowledge and quantitative information for detecting faults. On account of this reason, this paper proposes...
متن کاملImproving the Method of Location Identification and Determining the Effect of Each Flicker Source in Distribution Networks
Voltage flicker phenomenon is one of the main power quality problems in today's power networks. Before any compensation operation for this phenomenon, the location of each flicker sources must be identified and the effect of each of them on the network flicker value must be determined. Also, methods that require least number of monitoring points are more in demand due to the limitations of meas...
متن کاملA Probabilistic Three-Phase Time Domain Electric Arc Furnace Model based on analytical method
An electric arc furnace (EAF) is known as nonlinear and time variant load that causes power quality (PQ) problems such as, current, voltage and current harmonics, voltage flicker, frequency changes in power system. One of the most important problems to study the EAF behavior is the choice of a suitable model for this load. Hence, in this paper, a probabilistic three-phase model is proposed base...
متن کاملVoltage Flicker Monitoring Based on Virtual Instrument and Wavelet Packet Transform
This paper proposes a new method of monitoring and analyzing voltage flicker based on wavelet packet transform and virtual instrument, and establishes an arithmetic model of the system. First, through the wavelet package transform, we can extract the amplitude modulation waveform, get the accurate time when the voltage flicker occurs and stops, and count the frequency and amplitude of voltage f...
متن کاملCritical Voltage Flicker Detection based on Pair of Inter-harmonics Analysis Method
This paper presents a critical voltage flicker detection based on a pair of inter-harmonics analysis method. The proposed algorithm can be applied in any crowded human place for human awareness purpose. Moreover, the correlation between pair of inter-harmonics and critical voltage flicker is described in details and the related formulas have been derived as well. According to simulation and exp...
متن کامل