Optimisation of a Balanced Fast Field Echo Cine Sequence for the Assessment of Human Fetal Motor Function

نویسندگان

  • T. Hayat
  • J. Allsop
  • A. McGuinness
  • F. Ferrari
  • M. Rutherford
  • J. V. Hajnal
چکیده

T. Hayat, J. Allsop, A. McGuinness, F. Ferrari, M. Rutherford, and J. V. Hajnal Robert Steiner MRI Unit, Imaging Sciences Department, MRC Clinical Sciences Centre, Hammersmith Hospital, Imperial College London, London, United Kingdom, Perinatal Imaging Group, MRC Clinical Sciences Centre, Hammersmith Hospital, Imperial College London, London, United Kingdom, Department of Pediatrics and Neonatology, Modena University Hospital, Italy

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technical advances in MRI of non-CNS fetal structures

US is the modality of choice for routine fetal screening. Fast single-shot MR sequences have proved to be an useful imaging method in evaluating equivocal sonographic findings or assessing fetus with suspected anomaly which requires further clarification for management [1-3]. Most studies used T2-weighted sequences such as Half-Fourier single-shot turbo spin echo (HASTE, SSFSE) or fast-field ec...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

An exploration of the potential utility of fetal cardiovascular MRI as an adjunct to fetal echocardiography

OBJECTIVES Fetal cardiovascular magnetic resonance imaging (MRI) offers a potential alternative to echocardiography, although in practice, its use has been limited. We sought to explore the need for additional imaging in a tertiary fetal cardiology unit and the usefulness of standard MRI sequences. METHODS Cases where the diagnosis was not fully resolved using echocardiography were referred f...

متن کامل

MR assessment of left ventricular function: quantitative comparison of fast imaging employing steady-state acquisition (FIESTA) with fast gradient echo cine technique.

PURPOSE To evaluate the agreement of fast imaging employing steady-state acquisition (FIESTA) cine technique with segmented k-space fast gradient echo (GRE) cine technique when using them for assessment of cardiac function. MATERIALS AND METHODS Eleven MR cine studies were performed on six healthy volunteers and five patients, using FIESTA and fast GRE techniques. The quantitative measurement...

متن کامل

Optimization and initial experience of a multisection balanced steady-state free precession cine sequence for the assessment of fetal behavior in utero.

BACKGROUND AND PURPOSE The assessment of motor function is an essential component of neurologic examinations, which imaging studies have extended to the fetus. US assessment is hampered by a limited FOV, whereas MR imaging has the potential to be an alternative. Our objectives were to optimize a cine MR imaging sequence for capturing fetal movements and to perform a pilot analysis of the relati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008